Troubleshooting
4-6
SCM4000
Operator’s Guide/Tech Ref Manual
E248
Dem Cal Er
Rate Calculation Error - The total
data rate exceeds the capacity for
the given symbol rate and
modulation.
•
Increase the symbol rate,
move the modulation to a
higher throughput type (i.e.,
from 16QAM to 32QAM), or
decrease the rate on a
configurable channel.
•
Contact technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support.
E249
Carr Unlck
Carrier Unlock - The Demodulator
cannot lock to the incoming IF
signal.
•
Verify that a valid signal is
connected and that you have
the correct symbol rate and
modulation parameters
selected.
•
Contact technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support.
E24A
No Div Sig
Diversity signal is not detected.
Diversity is enabled, but the
modem cannot detect a valid
diversity connection.
•
Check diversity cables. Verify
diversity is enabled on the
companion Demodulator.
•
Contact technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support.
Table 4-3: SCM4000 Demodulator Primary Error Codes (Continued)
Error
Code
Error Message
Meaning
Suggested Operator Action
Suggested Technical Staff
Action
Содержание SCM4000
Страница 1: ...Manual Part No 400509 1 Rev A February 2006 Technical Reference Manual Single Carrier Modem SCM4000 ...
Страница 2: ......
Страница 14: ...Introduction 1 4 SCM4000 Operator s Guide This page intentionally left blank ...
Страница 234: ...Repair 6 2 SCM4000 Technical Reference Manual This page intentionally left blank ...
Страница 242: ...Theory of Operation 8 6 SCM4000 Technical Reference Manual This page intentionally left blank ...
Страница 250: ...Glossary A 8 SCM4000 Operator s Guide Tech Ref Manual This page intentionally left blank ...
Страница 266: ...Symbol Rate Calculations C 8 SCM4000 Technical Reference Manual This page intentionally left blank ...
Страница 274: ...Index 8 SCM4000 Technical Reference Manual This page intentionally left blank ...