Page 36
Software Configuration
thermoIMAGER TIM Connect
Using the option
Flag operation while recording
and
Use flag
the correction is activated even if
the camera is recording. If
Avoid flag
is chosen the camera will not be corrected while recording. The op-
tion
Use flag while skipped frames
is suitable at slow data capturing (3 Hz or less) as the correction
will take place automatically between two recorded images (correction time app. 250 ms).
i
The manual or automatic flag functionality is not available if the flag is externally controlled, e.g. via the
process interface input, see Chap.
4.5
.
Use the flag to protect the detector from potentially dangerous radiation (for example laser radiation).
> Damage of the detector
4.3.3
Detector Heating (Chip Temperature Mode)
The bolometer chip temperature can be set under
Configuration
and
Device
.
Standard (Floating)
means that the chip heater is off. The chip temperature results from the ambient temperature.
With
Automatic
, a predefined temperature is set. And a fixed chip temperature can be set with
Fixed
value
.
i
The detector heating (Chip temperature mode) setting is only available for the TIM series because there
is no chip heater integrated for the TIM 8 TIM 40 series.