background image

 

 

 

 

 

User Manual 

 

 

 

 

Copyright © 2011 - 2020 Opgal LTD, all rights reserved. 

The data contained in this document is  proprietary to Opgal LTD. It  is disclosed to the 
receiving party only for the sole purpose stated herein, and shall not be disclosed by the 
receiving party to any third party, and shall not be duplicated, used or disclosed in whole 
or in part for any purpose other than the purpose specifically stated. This publication, or 
any  parts  thereof,  may  not  be  reproduced  in  any  form  without  the  express  written 
permission of Opgal LTD. 

Содержание Therm-App MD Pro

Страница 1: ...rty only for the sole purpose stated herein and shall not be disclosed by the receiving party to any third party and shall not be duplicated used or disclosed in whole or in part for any purpose other...

Страница 2: ...ture 7 8 7 2 Moisture on Skin 7 8 7 3 Angle 7 8 7 4 Steady State 7 8 7 5 Establishing a Baseline 7 8 8 Getting started 8 9 9 Browser Support 9 10 10 Access the device 10 10 11 First time turning on 11...

Страница 3: ...RO Rev B 14 1 1 DATE and TIME 14 25 14 1 2 FILE UPLOAD 14 26 14 1 3 USERS 14 30 14 1 4 SUPPORT 14 31 15 Upgrading and Coupling a Therm App MD BASIC Camera to PRO version System Computer 15 32 16 Speci...

Страница 4: ...n Before starting to use be sure to read the following To avoid usage problems and accidents first read the Safety Instruction and Handling Precautions Also read this user manual to ensure that you us...

Страница 5: ...o not insert foreign objects or liquids into the product Do not use the system where flammable gases may be present This may cause an electric shock explosion or a fire If not in use do not leave the...

Страница 6: ...ial micro USB input for a technician s use only Warning Do not use this port unless specifically instructed to do so by an OPGAL technical manager Micro SD A saving media option for future use current...

Страница 7: ...asurement should not be solely or primarily relied upon to diagnose or exclude a diagnosis of COVID 19 or any other disease 2 Elevated body temperature in the context of use should be confirmed using...

Страница 8: ...r conditioner If unavoidable allow the camera to obtain a new steady state before use normally 10 minutes 7 2 Moisture on Skin Make sure to wipe down or dry damp skin such as from rain or sweat 7 3 An...

Страница 9: ...e mode by connecting the system s computer through a LAN to a remote PC or 2 Kiosk mode by connecting HDMI LCD monitor keyboard and mouse directly to the computer system Connect the system as it is su...

Страница 10: ...indows 1 At the first you must set the same IP address subnet on your PC 2 In Windows 10 open the Network and Internet Settings 3 Select Ethernet and then open Change adapter options 4 Perform right m...

Страница 11: ...n default settings 10 Create an administrator default username For example admin 11 Create a default password for the administrator user You can change the username and the password any time 12 It is...

Страница 12: ...H00AQ MD PRO Rev B 11 First time turning on Each time after connecting the system to the power supply an initial warming up procedure is started and may take several minutes A live B W video and a Cam...

Страница 13: ...ogin Logout change password menu 2 Address bar URL 3 Therm App MD Pro product brand name 4 Live View 5 HAMBURGER setting menu 6 Time Date Display 7 Quick access menu Voice Alarm Is Disable Voice Alarm...

Страница 14: ...vailable only for admin user 1 Select the ROI REFERANCE icon 2 Press on ADD ROI REFERANCE button 3 A small yellow square X V ROI will appear 4 The Icon should be placed on a location which has a stabl...

Страница 15: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 12 15 of 43 Document P N UM TAH00AQ MD PRO Rev B 12 2 Color Palette NONE GREEN INFERNO RAINBOW LAVA IRON VIRIDIS PSY...

Страница 16: ...y Celsius Fahrenheit Kelvin Automatic background temperature Checking the box will perform Automatic default background temperature compensation Background temperature 25 100 c You can define the back...

Страница 17: ...ential Opgal Propriety Page 13 17 of 43 Document P N UM TAH00AQ MD PRO Rev B 13 Main settings menu When pressing on the Hamburger icon on the left upper corner the left menu will pop up Pressing on TH...

Страница 18: ...n the main menu Under the Network sub menu you will find the following tabs IP Addresses Section allows the user to change and set the IP addresses and DNS server addresses HTTPS Connection Section al...

Страница 19: ...Obtain DNS servers automatically checkbox Press APPLY to save or CANCEL to dismiss the changes 13 1 3 Setting Manual DNS Server Addresses Please note This is applicable when synchronizing the time an...

Страница 20: ...onnection Section Please Note This option is applicable when either selecting a self signed certificate or uploading an existing certificate Press on HTTPS Connection in the Settings page to expand th...

Страница 21: ...v B 13 2 Certificates Tab Select Create Certificate Request for requesting a Secure Sockets Layer SSL certificate Fill in the following fields Common Name enter an IP address or system host name requi...

Страница 22: ...e Self Signed Certificate for generating a self signed Secure Sockets Layer SSL certificate Fill in the following fields Common Name enter an IP address or system Host name required State or Province...

Страница 23: ...nt P N UM TAH00AQ MD PRO Rev B Select Upload Certificate for loading an existing Secure Sockets Layer SSL certificate which originated from another source Press SELECT CERTIFICATE and browse to select...

Страница 24: ...l support Press EXPORT SITE to export site defaults with constant IP address or with DHCP properties o A compressed file in tgzx format is downloaded to the computer s Download folder o Export DHCP si...

Страница 25: ...Page 14 25 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 1 DATE and TIME Select Synchronizing with the browser time to sync the system with browser time Select Synchronizing with NTP to sync the sys...

Страница 26: ...ial Opgal Propriety Page 14 26 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 2 FILE UPLOAD Press SELECT FILE button to update a new firmware and browse to the relevant firmware file location Select...

Страница 27: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 14 27 of 43 Document P N UM TAH00AQ MD PRO Rev B Then press on the UPLOADFILE button to upload new version Look at the process BAR...

Страница 28: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 14 28 of 43 Document P N UM TAH00AQ MD PRO Rev B Press RESTART to reboot the system...

Страница 29: ...MD Pro User Manual Confidential Opgal Propriety Page 14 29 of 43 Document P N UM TAH00AQ MD PRO Rev B You can check if you are using the most updated version of the Therm App MD PRO by pressing on th...

Страница 30: ...o User Manual Confidential Opgal Propriety Page 14 30 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 3 USERS When entering the USERS tab as an admin you can manage users by adding removing and editin...

Страница 31: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 14 31 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 4 SUPPORT Special tab for Opgal technicians only...

Страница 32: ...e following instructions 1 By using LAN cable connect the system computer via a LAN connection to the Internet connection via a router 2 Connect the camera to one of the four USB 3 ports 3 Connect a k...

Страница 33: ...3 Document P N UM TAH00AQ MD PRO Rev B 8 The system will try to couple and calibrate the camera to the computer and the following screen will be displayed 9 After few minutes the system may display a...

Страница 34: ...ev B 10 From the menu go to NETWORK SETTINGS IP ADDRESS and check the both checkboxes a Obtain IP address automatically b Obtain DNS Servers automatically 11 Press on the APPLY button 12 From the popu...

Страница 35: ...e 15 35 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 This process may take several minutes 15 After few minutes a live B W video and a Camera is warming up message will appear 16 Wait to Camera is wa...

Страница 36: ...Hot cold threshold based pallets Manual and auto scale Measurement Settings Emissivity Reflected Temperature Statistical deep learning algorithm Color Palettes Rainbow Iron Vivid Grey Red Hot Blue Col...

Страница 37: ...herm App MD Pro Application OS Support Linux compliance with Ubuntu 18 04 Display Interface HDMI 2 0 x1 Storage Device 16GB eMMC Micro SD Slot x1 Ethernet 10 100 1000Base TX x 1 I O USB 3 2 Gen 1 x 4...

Страница 38: ...riety Page 17 38 of 43 Document P N UM TAH00AQ MD PRO Rev B Gross Weight 1 Kg 2 20 lb Net Weight 0 4 Kg 0 88 lb Operating Temperature 10 C to 40 C 14 F to 104 F Storage Temperature 45 C to 80 C 49 F t...

Страница 39: ...l In order to make this extended warranty effective you must contact the authorized reseller from whom you purchased the Product or Opgal local service center and notify them about the production faul...

Страница 40: ...t the prior written permission of Opgal Names and marks appearing on the Product are either registered trademarks or trademarks of Opgal and or its affiliates and or its licensors 11 OPEN SOURCE SOFTW...

Страница 41: ...communications However there is no guarantee that interference will not occur in a particular installation If the Product does cause harmful interference to radio or television reception which can be...

Страница 42: ...pneumatic tools and is set a at a level of pressure that is too high This can damage the detector and lens WARNING The device is designed to use 5V DC power supply only fed through its micro USB conne...

Страница 43: ...on Email info opgal com Phone 972 4 9953903 Fax 972 4 9953900 http www opgal com P O Box 462 Industrial Area 5 Karmiel 2161401 ISRAEL All specifications are subject to change without notice Last Updat...

Отзывы: