11. Hydraulic diagrams
ThermiStar L .. SP 01/03/10
86
Factory parameterization
Control
line
User
level
Function / Default value
Setting value
L 05 - 15
L 19 -
28
L 34 -
41
561-566 E
Timer setting 4 Monday
05:00 – 21:00
561-566 E
Timer setting 4 Tuesday
05:00 – 21:00
561-566 E
Timer setting 4 Wednesday
05:00 – 21:00
561-566 E
Timer setting 4 Thursday
05:00 – 21:00
561-566 E
Timer setting 4 Friday
05:00 – 21:00
561-566 E
Timer setting 4 Saturday
05:00 – 21:00
561-566 E
Timer setting 4 Sunday
05:00 – 21:00
2801 I
Condenser pump control
Temperature request ¦ Parallel condenser operation
Temperature request
2803
I
Run-on time condenser pump
120
2819
I
Prerun time source
5
2842
I
Condenser run time min.
0
2843
I
Condenser idle time min
10
2845
F
Reduction shut-off temp. Max
0
2853
O
Low pressure delay operational
5
2854
O
LP monitoring
Always ¦ No thawing
Always
2893
F
Number: DHW charging attempts
3
2951
I
Defrost release below OT
10
2954
O
Evaporator temp. Thawing end
5
2963
I
Time up to forced defrost
180
2964
I
Defrosting time max
20
2971
O
Thawing ventilator above
7
3010
O
Max. speed V'lator/Q'pump
40
60
5093
F
With solar integration
No ¦ Yes
No
5731 I
DHW controlling element Q3
None ¦ Charging pump ¦ Diverting valve
Diverting valve
5800
I
Heat source
Brine ¦ Water ¦ Air ¦ External
Air
5890 I
Relay output QX1
None ¦ Condenser stage 2 K2 ¦ Process reversing valve
Y22 ¦ Hot gas temperature K31 ¦ Electrical insert1 Flow
K25 ¦ Electrical insert2 Flow K26 ¦ Reversing valve
cooling Schi2 Y28 ¦ Delivery pump Q14 ¦ Cascade pump
Q25 ¦ Generator shut-off valve Y4 ¦ Electrical insert
TWW K6 ¦ Circulation pump Q4 ¦ Storage charge-over
pump Q11 ¦ TWW Intermediate circuit pump Q33 ¦
TWW Mixing pump Q35 ¦ Collektor pump Q5 ¦ Collector
pump 2 Q16 ¦ Solar pump ext.exchanger K9 ¦ Solar
control element buffer K8 ¦ Solar control element
sulphur bath K18 ¦ Electrical insert buffer K16 ¦ H1-
Pump Q15 ¦ H2-Pump Q18 ¦ H3-Pump Q19 ¦ Heating
cycle pump HkP Q20 ¦ 2. Pump stage HK1 Q21 ¦ 2.
Pump stage HK2 Q22 ¦ 2. Pump stage HKP Q23 ¦
Reversing valve cooling Y21 ¦ Air dehumidifier K29 ¦
Heat request K27 ¦ Cold request
Process reversing valve Y22
Содержание 98.30000-6324
Страница 1: ...ThermiStar L SP 01 03 10 ...
Страница 18: ...5 Technical Data ThermiStar L SP 01 03 10 18 5 2 Type plate Fig 4 Sample type plate ...
Страница 21: ...ThermiStar L SP 01 03 10 5 Technical Data 21 ...
Страница 39: ...ThermiStar L SP 01 03 10 6 Assembly 39 Fig 11 Sensor cable heat source intake 5 ...
Страница 68: ...8 Maintenance ThermiStar L SP 01 03 10 68 8 4 Spare part drawing and legend Fig 40 ...
Страница 88: ...Your notes ThermiStar L SP 01 03 10 88 ...
Страница 89: ...ThermiStar L SP 01 03 10 Your notes 89 ...
Страница 90: ...Your notes ThermiStar L SP 01 03 10 90 ...
Страница 92: ......