5. Technical Data
ThermiStar L .. SP 01/03/10
20
5.3 Technical
data
Air/water heat pumps* Thermistar L 05 SP to L 41 SP
ThermiStar L ..
05 SP 07 SP 10 SP 13 SP 15 SP 19 SP 28 SP 34 SP 41 SP
Output A2/W35* Nominal heating
capacity
kW 5,2 7,1 10,4 13,0 15,3 19,4 27,4 33,6 40,9
Power consumption condenser
kW
1,3 1,7 2,4 3,0 3,5 4,8 6,4 7,9 9,6
Cooling capacity
kW
4,0
5,6
8,1 10,0 12,0 14,9 21,3 26,1 31,8
Performance
no.
COP
3,7
3,9 4,0 3,7
4,0
3,9
Refrigerant
R 407 c for hot water temperatures up to 55°C
Refrigerant dosage
for max. 20 m line length**
kg 3,5 4,2 5,5 8,5 10,0 12,0 15,5 20,2 20,7
Refrigerant lines Liquid
(1) mm
10
12 15 18 22
Suction gas (2)
15
22
28
35
42
Thawing (3)
10
12
15
18
Nominal current consumption
A
3,0
4,0 5,4 6,5 7,4 12,6 14,3 16,2 18,6
Operating current, max.
A
5,0
5,2 8,2 10,1 11,8 16,0 21,0 25,0 32,0
Starting current with soft-start
A
13,0 20,0 25,8 32,0 37,0 49,5 63,5 83,5 99,0
Blocked rotor current
A
26,0
40,0 51,5 64,0 74,0 99,0 127,0 167,0
198,0
Power circuit breaker / Automatic
circuit breaker, slow
A 3x10 3x16
3x20
3x25 3x32
3x40
3x63
Recommended wire gauge
mm²
1,5
2,5
4,0
6,0
10,0
Electrical connection
Compressor
Control
current
3NPE, 400 V
1NPE, 230 V
Protection class heat pump
IP 40 (according to EN 60529)
Protection class split evaporator
IP 54 (according to EN 60529)
Evaporated
air
flow
rate,
nominal m³/h 2645 2570 3330 5220 5220 6670 10820 16010 14800
Sound
pressure
at
5
m
dB(A)
32 32 38 35 35 41 43 53 53
Mass flow heating system nomi-
nal
kg/h 900 1220 1790 2240 2630 3340 4700 5780 6900
Pressure loss heating water at
nominal flow rate
kPa 3,0 3,4 4,7 5,3 5,8 3,2 4,5 4,2 5,2
Heating connection
ET“ 1
1½
Outside dimensions WxDxH in-
ner part
mm 690x600x900
1030x730x900
Outside dimensions WxDxH
outer part
mm
1230x880x1030 2155x880x1030 3080x880x1030
Weight
of
inner
part
kg 107 120 140 160 175 200 207 217 225
Weight of outer part
kg
66
73
80
138
152
202
223
* Heating capacity and COP at A2/W35 as well as source side 3 K and heating side 10 K spread
** When changes to refrigerant lines lead to lengths exceeding 20 m, refrigerant dosage will change as follows:
Pipe with max. Ø 22 mm +/- 100 g/m, pipe with max. Ø 28 mm +/- 150 g/m, pipe with max. Ø 35 mm +/- 200 g/m
NOTE!
Refrigerant R407C for heating water temperatures up to H55°C.
Содержание 98.30000-6324
Страница 1: ...ThermiStar L SP 01 03 10 ...
Страница 18: ...5 Technical Data ThermiStar L SP 01 03 10 18 5 2 Type plate Fig 4 Sample type plate ...
Страница 21: ...ThermiStar L SP 01 03 10 5 Technical Data 21 ...
Страница 39: ...ThermiStar L SP 01 03 10 6 Assembly 39 Fig 11 Sensor cable heat source intake 5 ...
Страница 68: ...8 Maintenance ThermiStar L SP 01 03 10 68 8 4 Spare part drawing and legend Fig 40 ...
Страница 88: ...Your notes ThermiStar L SP 01 03 10 88 ...
Страница 89: ...ThermiStar L SP 01 03 10 Your notes 89 ...
Страница 90: ...Your notes ThermiStar L SP 01 03 10 90 ...
Страница 92: ......