SECTION 6 : OPERATION OF CONTROL PANEL
78
Table 6-1 : Menu Display Pages
FUNCTION
LINE
DESCRIPTION
REMARKS
Power up display page
POWER UP PAGE
1
ST
MH AUTOMATION
This page is displayed for 2 seconds
after power up. This page displays the
type of control and software version
number. During the power up delay
time, the THYROMAT status relay is de-
energised.
2
ND
This page shows all the alphabetic
letters and numbers for a period of
approximately 2 seconds, followed by
the software version numbers for
Control Card and Panel
3
RD
4
TH
C Copyright 2001
Default display page
STATUS MONITORING
PAGE
1
ST
Joystick position and speed %
The THYROMAT BD automatically
displays this page after the power up
delay time. To toggle between this page
and the MOTOR CURRENTS page
press the MENU key:-
2
ND
Phase Shifter reference and Overload
capacity
3
RD
Status
4
TH
Drive healthy (drive status)
Second display page
MOTOR 3 PHASE
CURRENTS
MONITORING PAGE
1
ST
Joystick position and speed %
This page displays the current
transformer inputs, take note that the
reference and speed functions are also
displayed. To return to STATUS
MONITORING page, press the MENU
key.
2
ND
Phase Shifter reference and Overload
capacity
3
RD
CT1 CT2 CT3
(Current transformer input)
4
TH
000 000 000
(Current transformer value in amperes)
6.2.
SUPPLEMENTARY DISPLAY PAGES "SCROLL MENU"
To enter this menu, press the key marked “PAR”, the typical displayed page is illustrated in figure 6-2.
Figure 6-2 : Typical Displayed Page
Scroll up
or down using the “UP” and “DOWN” keys to select the desired function.
6.2.1. Parameters
This function allows the operator to scroll through and change the settings of the pre-loaded default parameters.
Once this page has been accessed it can only be exit
ed by pressing the “SAVE” key. When the “SAVE” key is
pressed all information is saved (including any changes) and the display reverts back to the main display page.