Revision 8.6
SECTION 3 : TRAVEL PARAMETERS
41
23
Brake Plug Soft
Brake Plug Soft
Yes or No
-
No
24
Load defaults
Load Defaults
Yes or No
-
No
NOTE: All Travel Control software versions CTT01.XX must be used with Control Panel software
versions 9.XX.
3.4.
PARAMETER DESCRIPTIONS
– TRAVEL
The following paragraphs detail the various travel parameters.
3.4.1.
Current Transformer Ratio
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
1
CT Ratio
CT ratio
50:1 to 3000:1
-
50:1
This parameter selects a current transformer ratio (CT ratio). Only CT ratios from the list can be used.
The available CT ratios are:
THE AVAILABLE CT RATIO’S ARE
50:1
100:1
200:1
300:1
400:1
500:1
600:1
800:1
1000:1
1200:1
1500:1
2000:1
2500:1
3000:1
Note
CT’s are optional for all travel applications.
3.4.2.
Current Transformer Enable
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
2
CT Enable
CT’s enable
Yes or No
-
Yes
By selecting “Yes” current monitoring and the overload thermal model is enabled. Selecting “No” all the
Current related measurements are disabled. This means that there is no monitoring of current overload,
unbalance current and over current.