U
U
s
s
e
e
r
r
M
M
a
a
n
n
u
u
a
a
l
l
Revision 8.6
SECTION 3: TORQUE PARAMETERS
50
3.5.
TORQUE APPLICATION PARAMETERS LIST
Table 3-3 lists the typical parameter settings for software version CTT01.xx Torque applications.
Table 3-3: Torque Parameter List
NO
PARAMETER
DESCRIPTION
SCALE
INCREMENT
DEFAULT
1
CT Ratio
CT ratio
50:1 to 3000:1
-
200:1
2
CT Enable
Enable CTs
Yes or No
-
Yes
3
Motor Current
Motor full load current
< 60% of CT
ratio
-
70A
4
Overload class
Overload class type
5 to 10
-
5
5
Notch 1 Voltage
Voltage applied until N1 delay complete
30% to 100%
1
50%
6
Notch 2 Voltage
Voltage applied after N2 delay complete
30% to 100%
1
60%
7
Notch 3 Voltage
Voltage applied after N3 delay complete
30% to 100%
1
70%
8
Notch 4 Voltage
Voltage applied after N4 delay complete
30% to 100%
1
100%
9
Notch 1 Plug
Plugging Voltage applied when N1 is
selected in the opposite direction
30% to 100%
1
50%
10
Notch 2 Plug
Plugging Voltage applied when N2 is
selected in the opposite direction
30% to 100%
1
60%
11
Notch 3 Plug
Plugging Voltage applied when N3 is
selected in the opposite direction
30% to 100%
1
70%
12
Notch 4 Plug
Plugging Voltage applied when N4 is
selected in the opposite direction
30% to 100%
1
80%
13
Notch 2 Delay
Delay before N2 Voltage can be applied
to the motor
50ms to 9950ms
50ms
2000ms
14
Notch 3 Delay
Delay before N3 Voltage can be applied
to the motor
50ms to 9950ms
50ms
2000ms
15
Notch 4 Delay
Delay before N4 Voltage can be applied
to the motor
50ms to 9950ms
50ms
2000ms
16
Voltage Ramp
Ramp time to voltage of selected notch
200ms
17
Brakes ON Speed
Brake application speed
2% to 10%
1
5%
18
Max Stall V
Maximum Stall Voltage
20% to 80%
5%
70%
19
Minimum Start V
Minimum Start Voltage
10% - 80%
5%
30%
20
Ph Shift Off Tim
Phase shifter off time delay
60 to 240 ms
20 ms
100 ms