Vega EMS-1 Operating Manual
Page 15
Label:
Enter a label to suit your fuel flow input so you can identify it easily.
K-Factor:
The K-Factor is the number of pulses generated by the fuel flow sender for one Litre of fuel. The dual range fuel flow
sender supplied by MGL Avionics has a K-Factor of 7000 in the low flow mode (jet installed) and 1330 for the high flow
mode (no jet installed). You can use the K-Factor to calibrate your fuel flow sender. See the installation section for more
details on how to calibrate and install the fuel flow sender.
Mode:
Select if you want to measure fuel flow using a fuel flow sender or by using fuel injectors.
Injector:
Select whether the EMS-1 fuel flow input is connected to the high or low side fired fuel injector.
Data:
Select the data source of the RPM signals. Options include internal (using the internal electronics within the EMS-1) or
from an optional external RDAC unit.
RDAC Address:
Select the CAN address of the RDAC unit.