Current Sensor
Current Sensors
MGL Avionics Closed Loop Current Sensor
Volts
Voltage measurement range
Up to 32Vdc
Voltage resolution
0.1V
OAT Probe
OAT Temperature Sender type
Semiconductor LM335 (STMicroelectronics)
RTC
Internal battery type
CR2032
8 Operating the alarms
The alarm output can be used to switch an external alarm indicator. The external alarm switch is an open collector
transistor switch to ground with a maximum rating of 0.25A DC. It is possible to wire the alarm contacts of several
Stratomaster instruments in parallel should this be desired. To avoid false activation of the alarms, the alarm function is
only active 10 seconds after the instrument has powered up.
9 Firmware Upgrading
The EMS-1 can be upgraded in the field by connecting the RS232 port to a PC and running the firmware update program.
Note that only the RS232 port can be used to upgrade the firmware.
Please see the Vega firmware upgrading document for more information.
10 Changing the internal battery
The EMS-1 uses an internal battery to supply power to the clock. You will need to replace the internal battery if you find
the EMS-1 looses time when you switch off the main power. This battery is of type CR2032. It is used in many calculators
and similar equipment and is easy to obtain. Remove the 2 securing nuts next to the D15 connector and remove the unit
from its enclosure. The battery holder is located on the circuit board behind the display. Observe correct polarity when
installing a new battery. The side marked “+” will be viewable once the battery is inserted.