Low Caution:
Enter the pressure value for the low caution. This is the upper value of the lower yellow band.
Low Alarm:
This enables or disables the manifold pressure low alarm.
Low Alarm:
Enter the pressure threshold for when the low alarm must be activated. Any pressure below this value will activate the
alarm.
Filter:
This function can be used to select the signal filter time constant. Selections are
"NONE"
,
“FAST”
or
“SLOW”
. This
selection influences the rate at which your manifold pressure can change its reading.
Cal:
The sender in the RDAC is shipped uncalibrated. To calibrate the manifold pressure, compare and adjust the calibration
factor until the manifold reading is the same as the barometic pressure. The manifold pressure can only be calibrated in
mB.
RDAC Address:
Select the CAN address of the RDAC unit.