The Rotax 912iS ECU Oil temperature is mapped to the EMS-1 Analog CH 1 (renamed to Oil Temp Setup), Rotax 912iS
ECU Oil Pressure to the EMS-1 Analog CH 2 (renamed to Oil Press Setup) and the Rotax 912iS ECU Coolant
temperature to the EMS-1 Analog CH 3 (renamed to Coolant Temp Setup). These channels need to be setup accordingly.
The Rotax ECU transmits various status messages. These can be observed in the Rotax 912iS main display pages,
Rotax 912iS Direct Connection
The EMS-1 can be connected directly to the Rotax 912iS ECU.
As shown on this diagram, connect the CAN bus ECU lanes A and B together and then connect to the EMS-1 CAN
inputs.
Do NOT add CAN termination resistors to this connection as both ECUs have these built in.