![MGL Avionics Vega EMS-1 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/mgl-avionics/vega-ems-1/vega-ems-1_operating-manual_1783287047.webp)
Vega EMS-1 Operating Manual
Page 47
7 Specifications
Operating Temperature Range
-20ºC to 50ºC (-4ºF to 122ºF)
Storage Temperature Range
-30ºC to 80ºC (-22ºF to 176ºF)
Power Supply
8 to 30Vdc
Current Consumption
Approx. 80mA @ 13.8V (backlight highest setting), 36mA @13.8V
(backlight lowest setting)
Display
1.8” 160x128 pixel active matrix TFT display.
1000 cd/m2
Sunlight readable with anti-glare coating
LED Backlight is user configurable
Alarm Output
Open collector transistor switch to ground
Maximum rating 0.25A
ADC
12 bit
Dimensions
see Vega series dimensional drawing
Enclosure
2 1/4” (57mm) ABS, black in color, front or rear mounting. Flame retardant.
Weight
Approx. 120 grams (Instrument excluding cables)
Non-volatile memory storage
100000 write cycles
RPM Inputs
RPM input 1
Range: 0-99999 RPM.
Minimum signal for stable display: 5Vpp.
Fully A/C coupled, maximum v/- 40V.
RF noise filter plus Schmitt trigger based input
RPM input 2
Range: 0-99999 RPM.
TTL level input
Required input voltage swing: less than 1.5V to more than 3.5V.
Maximum input voltage range -5V to +18V
RF noise filter and Schmitt-trigger based input.
Sensor Output Voltage
+5Vdc. Max 50mA
Fuel Flow Input
Fuel Flow input
RF noise filter plus Schmitt trigger based input
External pull up resistor may be required
Sensor Output Voltage
+5Vdc. Max 50mA
Thermocouples
Type
J-type, K-type and E-Type
Measurement range
EMS-1 Internal amplifier
K-Type: -100ºC to 1200ºC (-148ºF to 2192ºF)
J-Type: -100ºC to 1100ºC (-148ºF to 2012ºF)
E-Type: -100ºC to 800ºC (-148ºF to 1472ºF)
Technology
Fully cold junction compensated using a precision internal temperature
reference and built in thermocouple linearization tables
Measurement accuracy
+/- 5 degrees typical over full temperature range, subject to quality of probe
used. We recommend MGL Avionics EGT and CHT probes
Inputs
Differential, can use grounded and isolated probes
Common mode voltage range
-2V to +3V
Channels
4 using the internal electronics, 12 using the optional external RDAC
Analog Input Channels
Analog Input Channels
4 Total. 3 (With dipswitch programmable pullup resistor), 1(With fixed pull
up resistor)