![Metronix DIS-2 48/10 FB FS STO Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/metronix/dis-2-48-10-fb-fs-sto/dis-2-48-10-fb-fs-sto_manual_1780032076.webp)
Page 76
Function and data blocks for SIEMENS S7
PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
13.2.2.2 FB_velocity (FB 43 speed control)
Parameters:
-
DB_nr_velocity:
The number of the data block containing the data for speed control mode (INT)
-
DB_nr_actual_value:
The number of the data block containing the actual value data (INT).
Inputs:
-
drive_enable:
Activation of the controller enabling in speed control mode. The speed setpoint takes
effect depending on the other inputs of the function block.
-
hold:
If this input is set, the speed setpoint is blocked. The drive slows down to standstill as
quickly as possible. When the input is reset, the motor accelerates along the
paramerized setpoint ramp to reach the adjusted speed setpoint.
-
jog_pos:
If this input is set, the drive accelerates with the set acceleration of the setpoint ramp until
it reaches the speed parameterized in position set „Tipp & Teach“.
If there is a falling edge at this input, the drives slows down to standstill with the set
deceleration of the setpoint ramp.
-
jog_neg:
If this input is set, the drive accelerates with the set acceleration of the setpoint ramp until
it reaches the speed parameterized in position set „Tipp & Teach“.
If there is a falling edge at this input, the drives slows down to standstill with the adjusted
deceleration of the setpoint ramp.