![Metronix DIS-2 48/10 FB FS STO Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/metronix/dis-2-48-10-fb-fs-sto/dis-2-48-10-fb-fs-sto_manual_1780032056.webp)
Page 56
Manufacturer-specific parameter numbers
PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
PNU
1011
Name
Accelerations for Velocity Control
Subindex
0
Name
Acceleration Velocity Control
Data type
UINT32
Access
rw
Unit
Physical unit of PROFIBUS acceleration
Value range
-
Default value
10.000 (rpm)/s
Subindex
1
Name
Deceleration Velocity Control
Data type
UINT32
Access
rw
Unit
Physical unit of PROFIBUS acceleration
Value range
-
Default value
10.000 (rpm)/s
The parameter
All Accelerations Velocity Control
provides access to the acceleration and
deceleration ramp for both directions of rotation. If the same value is intended for all 4 parameters, only
one data value has to be transmitted. This value is then used internally for all four acceleration types. It
has to be taken into consideration that during a read operation only the current value of the
deceleration ramp for the positive direction of rotation is read. The user has to make sure that reading
a value is sufficient. This can be ensured, for example, by reading a value once and then writing it
back.
Subindex
2
Name
All Accelerations Velocity Control
Data type
UINT32
Access
rw
Unit
Physical unit of PROFIBUS acceleration
Value range
-
Default value
10.000 (rpm)/s