Manufacturer-specific parameter numbers
PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
The parameter
All Accelerations
Positioning
provides access to the acceleration and deceleration
ramp. If the same value is intended for both parameters, only one data value has to be transmitted.
This value is then used internally for both acceleration types. It has to be taken into consideration that
during a read operation only the current value of the deceleration ramp is read. The user has to make
sure that reading a value is sufficient. This can be ensured, for example, by reading a value once and
then writing it back.
Subindex
5
Name
All Accelerations Positioning
Data type
UINT32
Access
rw
Unit
Physical unit of PROFIBUS acceleration
Value range
-
Default value
10,000 (rpm)/s
10.2.3
PNU 1002: Start Set Number
This parameter is used to select the position data set which is started through control word 1 following
a positioning start command. The servo positioning controller contains up to 64 storable standard
position data sets. These data sets can be selected unambiguously on the basis of 8 bits.
PNU
1002
Subindex
0
Name
Start Set Number
Data type
UINT8
Access
rw
Unit
-
Value range
0 .. 68
0..63:
Standard position data sets
64..67:
Reserved
68:
Position data set PROFIBUS
Default value
68 (Position data set PROFIBUS)
10.2.4
PNU 1003: Position Profile Type
By using this parameter the jerk-free ramp is activated. The time is not adjustable. It is set
automatically on the maximum time when activation.
If the time is changed by DIS-2 ServoCommander
TM
parameterisation software, the value which is read
back via PROFIBUS supplies the value 2.