![Metronix DIS-2 48/10 FB FS STO Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/metronix/dis-2-48-10-fb-fs-sto/dis-2-48-10-fb-fs-sto_manual_1780032051.webp)
Manufacturer-specific parameter numbers
Page 51
PROFIBUS-Manual Servo positioning controller DIS-2 48/10 FB
Version 2.0
This PNU can also be used to parameterize parameters for jogging, for example. To do so, the
position data set number has to be set accordingly. Then the jogging speed can be set with the help of
the profile velocity.
PNU
1001
Name
Position Data
Subindex
0
Name
Target Position
Data type
INT32
Access
rw
Unit
Physical unit of PROFIBUS position
Value range
-
Default value
0
Subindex
1
Name
Profile Velocity
Data type
INT32
Access
rw
Unit
Physical unit of PROFIBUS velocity
Value range
-
Default value
1000 rpm
Subindex
3
Name
Acceleration Positioning
Data type
UINT32
Access
rw
Unit
Physical unit of PROFIBUS acceleration
Value range
-
Default value
10,000 (rpm)/s
Subindex
4
Name
Deceleration Positioning
Data type
UINT32
Access
rw
Unit
Physical unit of PROFIBUS acceleration
Value range
-
Default value
10,000 (rpm)/s