8.7.2004
Rev. 1.0
Installation
22
5.11
Gas supply connection
This appliance is designed to burn natural and liquid gas. To find out the category to
which this appliance belongs in the country where it is installed, please refer to the table
below.
Table 1: gas categories and pressure values
COUNTRY
APPLIANCE CATEGORY
GAS
RATED
PRESSURE
(mbar)
MINIMUM
PRESSURE
(mbar)
MAXIMUM
PRESSURE
(mbar)
Belgium France
II2E+3+
G20
20
17
25
G25
25
17
30
G30
28
25
35
G31
37
25
45
Spain Great Brit-
ain Ireland
Greece
II2H3+
G20
20
17
25
G30
28
25
35
G31
37
25
45
Italy Italian
Switzerland Por-
tugal
II2H3+
G20
20
17
25
G30
30
25
35
G31
37
25
45
Austria German
Switzerland
II2H3B/P
G20
20
17
25
G30
50
42.5
57.5
G31
Germany
II2ELL3B/P
G20
20
17
25
G25
G30
50
42.5
57.5
G31
Finland
II2H3B/P
G20
20
17
25
G30
30
25
35
G31
Denmark
II2H3B/P
G20
20
17
25
G30
30
25
35
G31
Sweden
II2H3B/P
G20
20
17
25
G30
30
25
35
G31
Luxembourg
I2E
G20
20
17
25
Netherlands
II2L3B/P
G25
25
20
30
G30
30
25
35
G31
Norway
I3B/P
G30
30
25
35
G31
Hungary
II2HS3B/P
G20
25
20
33
G25.1
G30
30
25
35
G31
Czech Republic
II2H3B/P
G20
20
17
25
G30
30
25
35
G31
Содержание 92/04 CG1P
Страница 2: ...8 7 2004 Rev 1 0...
Страница 4: ...8 7 2004 Rev 1 0...
Страница 46: ...6SC00476 wiring diagram 96 04 CGEE 96 04 CGEE2P 96 04 CGEEP 3 N PE 400V 50 60 Hz...
Страница 48: ...6SC00477 wiring diagram 94 04CGE 94 04CGE1P 94 04CGEP 3 N PE 400V 50 60 Hz...
Страница 50: ...6SC00478 wiring diagram 94 04CGGE 94 04CGEE1P 94 04CGEEP 3 N PE 400V 50 60 Hz...
Страница 52: ...6SC00480 wiring diagram 98 04CGE 98 04CGE2P 98 04CGEP 1 N PE 230V 50 60 Hz...
Страница 74: ......