8.7.2004
Rev. 1.0
Operating instructions
11
4.2.2
Switching the open fire burners on and off
•
To light the pilot flame, press and turn the knob in a counterclockwise direction
(item 2 in Fig. 3);
•
hold the knob down and at the same time move a flame closer to the pilot;
•
after lighting the pilot flame, hold the knob down for about 15 seconds so the ther-
mocouple can be heated. Repeat the operation if, after releasing the knob, the pilot
flame goes out;
•
burner power control range is between item 3 and item 4 in Fig. 3;
•
to switch off the main burner, turn the knob in a clockwise direction on item 2;
•
to switch off also the pilot flame, turn the knob in a clockwise direction on item 1.
Fig. 3
1.
OFF position
2.
PILOT FLAME IGNITION position
3.
MAXIMUM position
4.
MINIMUM position
Содержание 92/04 CG1P