8.7.2004
Rev. 1.0
Adjustment instructions
34
6.5
Adjusting the minimum setting
To operate with liquid gases, remove the knobs, insert a screwdriver and tighten the screw
in item 1 in Fig. 18.
Fig. 18
1.
Screw for adjusting the minimum setting
2.
Gas inlet union position
3.
Thermocouple union position
4.
Gas outlet union position
5.
Pilot flame union position
For other types of gas, adjust the screw until the flame is stable and uniform, proceeding
as follows:
•
unscrew the screw shown in item 1 in Fig. 19;
Fig. 19
1.
Screw
•
connect a liquid pressure gauge (for example, a U-shaped pressure gauge, mini-
mum subdivision 0.1 mbar) or a digital pressure gauge;
•
start up the appliance (as described in the instruction manual of the appliance).
The gas pressure with the burner operating on minimum must correspond to the pressure
values shown in “Table 2: specifications for burners and nozzles” under the entry “Re-
duced pressure (mbar), minimum”.