TROUBLE
POSSIBLE CAUSES
MAINTENANCE
FOR THE USER
FOR THE TECHNICAL
SUPPORT SERVICE
OPEN FIRES
Pilot burner won’t
light:
pressure drop in gas sup-
ply pipe;
contact the gas utility compa-
ny;
clogged nozzle;
remove the dirt from the noz-
zle;
gas valve damaged;
replace it;
After releasing the
knob, the pilot burner
goes out:
valve knob has not held
down or it has held down
not enough time to allow
the thermocouple to get
hot;
repeat the ignition;
thermocouple faulty;
replace it;
gas valve damaged;
replace it;
Pilot flame stays lit, but
burner won’t light:
pressure drop in gas sup-
ply pipe;
contact the gas utility compa-
ny;
clogged nozzle;
remove the dirt from the noz-
zle;
gas valve damaged;
replace it;
gas outlet holes on the
burner crown are
clogged;
clean the crown;
burner components are
not placed one over the
other correctly;
place them properly.
Turning the fires igni-
tion knob from max. to
min., the burner
switches off:
minimum level is too
low;
adjust the minimum level (see
chapter “Adjusting the mini-
mum level” in the section “Ad-
justment instructions”).
Содержание 92/04 CG1P
Страница 2: ...8 7 2004 Rev 1 0...
Страница 4: ...8 7 2004 Rev 1 0...
Страница 46: ...6SC00476 wiring diagram 96 04 CGEE 96 04 CGEE2P 96 04 CGEEP 3 N PE 400V 50 60 Hz...
Страница 48: ...6SC00477 wiring diagram 94 04CGE 94 04CGE1P 94 04CGEP 3 N PE 400V 50 60 Hz...
Страница 50: ...6SC00478 wiring diagram 94 04CGGE 94 04CGEE1P 94 04CGEEP 3 N PE 400V 50 60 Hz...
Страница 52: ...6SC00480 wiring diagram 98 04CGE 98 04CGE2P 98 04CGEP 1 N PE 230V 50 60 Hz...
Страница 74: ......