Merloni Elettrodomestici
DISHWASHER EVO3
Service manual
EN
03-05-20/0
46-54
Language Issue/Edition
Page
8
EVO3 TABLE OF ALARMS
Key
Selector switch: selector switch models
LED: LED models
Display LCD: LCD readout models
Duration of fault: the time between the occurrence of the fault and when it is signalled
Overflow
alarm
The overflow alarm is signalled 9 seconds after the base pan float switches
from normally open to closed. All water fill processes are stopped, only the
drain pump stays on.
ALARM NAME
DISPLAY
DURATION OF FAULT
Programme selector
LED
LCD readout
Overflow
LED 1
LED programme 3
TO 01
9 sec.
Solenoid broken
LED 2
LED programme 4
TO 02
9 sec.
NTC circuit
Led 3
LED Programme 5
TO 04
9 sec.
Timeout heating water
LED 4
LED programme 6
TO 08
60 min.
Timeout draining
LEDs 1 and 2
LEDs programmes
3 and 4
TO 03
4 min.
Timeout filling
LEDs 2 and 3
LEDs programmes
4 and 5
TO 06
1 min. 30 sec.
Clogged filters
LEDs 1 and 3
LEDs programmes
3 and 5
TO 05
After filter cleaning cycle
fails
Software setup
LEDs 1 and 4
LEDs 1 and 4
TO 09
1 sec.
Heating element circuit
LEDs 2 and 4
LEDs programmes
4 and 6
TO 10
9 sec. if closed
pressure switch
Hardware version
LEDs 3 and 4
LEDs 3 and 4
TO 12
1 sec.
Communication not
possible
TO 99
N.B.
When a fault occurs with the dishwasher in Stand By mode (models with LCD readout and
graphics display), the fault is indicated on the display and a “safety procedure” started where
applicable.
This does not happen when the dishwasher is Off (models with Selector switch or LED).
LED programme 1
LED programme 6
LED 1
LED 4