Merloni Elettrodomestici
DISHWASHER EVO3
Service manual
EN
03-05-20/0
33-54
Language Issue/Edition
Page
5.7
Connection
Fill valve connection
Flow of 4l/m
230V~ power supply
Turbine 217 impulses/s
Drain pump connection
Synchronous motor
230V~ power supply
With the drain pump and the wash pump connected in series, the drain pump can be activated a lower voltages than the mains
supply
FILL SOLENOID
VA A J006 (Input turbine J006)
TURBINE
Q1
TRIAC
NEUTRAL
LINE
Q1
TRIAC
NEUTRAL
DRAIN PUMP
WASH PUMP
LINE