8
•
Four 6 x 25 (TX25 bit) screws for fixing the wallbox housing to the mounting plate (included)
•
If required: Wall plugs suitable for the mounting substrate (included: 10 x 50 nylon wall plugs)
•
Spirit level if required (not included)
DANGER!
Always observe the 5 golden rules of electrical installation:
1. Cut off all voltage sources
2. Secure all cut-off devices
3. Verify absence of voltage
4. Ground and short-circuit
5. Cover or bar access to adjacent components under voltage
Always deactivate the MCB(s) and RCCB allocated to the wallbox in the domestic power supply before you begin installa-
tion. Also ensure that the MCB(s) and RCCB cannot be reactivated during installation. Otherwise, there is a risk of severe
injury through electric shock or even death!
Proceed as follows to drill the holes using the mounting plate:
1. Ensure that a sufficiently dimensioned power supply is available at the desired installation site. Otherwise, a power supply
must be installed especially.
2. The mounting plate has pre-molded cable inlets for the power supply on
its upper edge as well in the middle of its surface. According to the power
supply at the installation site (and as required), please remove one of the
plastic tongues intended for the power supply cable with a suitable pair of
pliers, a cutter or drill.
83
3. Place the mounting plate on the chosen mounting surface: Use a spirit
level if required. Mark the drill holes.
4. Drill the mounting holes as marked (Ø 10 mm). Insert the supplied wall
plugs for the mounting screws if required.