background image

7

Mercedes-Benz Wallbox

 | Preparations, installation and taking into operation 

• 

The wallbox meets the requirements for outdoor installation. Outdoors, the wallbox should only be installed in covered loca-
tions that provide sufficient protection from weather-related pollution. 

Requirements for the power supply

The following standards must always be considered for the electrical installation of the Mercedes-Benz Wallbox:

• 

All regulatory requirements for low voltage installations according to IEC 60364-1 and IEC 60364-5-52 apply.

• 

Model variant A0009060307 is intended for the rated voltage indicated on the product label.

• 

The installation site must offer a sufficiently dimensioned power supply according to HD 60364-7-722:2012 (see also 
“Guidelines & Norms” on page 24): This power supply must be reserved exclusively for the wallbox and must not be used 
to supply other electrical devices.

• 

If necessary, a separate power supply must be installed that is intended exclusively for connecting the wallbox and com-
plies with the general requirements for cabling and building infrastructure. 

• 

Depending on the desired rated power, the installation of the wallbox may need to be registered with and/or approved by 
the local electricity grid operator. Please consult the local regulations of your electricity grid operator.

• 

Cable dimensions must be adjusted according to the desired rated power and other aspects (such as cable length, mate-
rial, cabling method etc.). The terminal blocks in the wallbox are designed for cable dimensions of up to 16 mm

2

.

• 

The power supply cables may be installed above or below the wall surface: The mounting plate provides alternative cable 
inlets at the top and at the rear.

• 

The power supply for the wallbox must always be protected by its own MCB and RCCB (at least Type A): Please always 
observe current national regulations regarding the selection of MCB and RCCB. Depending on the country, an RCCB with a 
different tripping characteristic (e.g. Type B) may be prescribed. 

• 

The wallbox does not have a dedicated ON/OFF switch: If you want to take the wallbox out of operation, you must always 
switch the upstream domestic MCB(s) and RCCB to the 0 (OFF) position.

• 

Please always ensure that the installation requirements listed in this manual are complied with. Disregard or actions to 
the contrary may lead to severe injury by electric shock or even death. In addition, in case of contravention of the notices 
given, the proper operation of the wallbox cannot be guaranteed.

PLEASE NOTE!

In some countries, the above mentioned requirements are different from the prerequisites for connecting to the local 
power grid. In this case, the wallbox must be connected in accordance with the respective type of mains power connec-
tion for the country of installation. You can find an overview of country-specific mains connection schemes on page 26 
in this manual or on the 

www.yourwallbox.de

 website using the following link:  

www.yourwallbox.de/Mains_Connection_Schemes

Mechanical installation of the mounting plate

After determining the mounting site for the wallbox, you can begin with mechanical installation. For installation you will need 
the following components:

• 

Power drill or cordless drill (not included)

• 

Drill bit Ø 10 mm, appropriate for the wall substrate (not included)

• 

Screwdriver with flat head (2.5 mm blade width), Phillips head (PH1) and torx head (TX40, TX25, TX20, TX10) bits

• 

Mounting plate (included)

• 

Pliers or cutter for breaking or cutting out the cable inlet in the mounting plate (not included)

• 

Four 8 x 60 wafer head (TX40 bit) screws for fixing the mounting plate (included)

Содержание 3W72M2

Страница 1: ...Mercedes Benz Wallbox Installation manual for specialist electrical contractors ...

Страница 2: ...ocal Mercedes Benz technical support This manual in its entirety or in parts must not be reproduced stored electronically or otherwise transmitted electronically electrically mechanically optically chemically by photocopy or as an audio recording without express written permission Version 1 1 MB IM Wallbox 2017 03 06 Article No 0301482_c ...

Страница 3: ...tion site 6 Requirements for the power supply 7 Mechanical installation of the mounting plate 7 Taking the wallbox into operation 11 Error detection and solutions 13 Disruptions to the operation of the wallbox and solutions 13 Error codes and solutions 13 Setup and testing modes 16 Taking the product out of and back into operation 20 Returning your wallbox 20 Appendix 21 Technical specifications 2...

Страница 4: ...iv ...

Страница 5: ...uired for installing the wallbox taking it into operation as well as for resolving malfunctions during operation For quick and easy reference certain sections of this manual are specially formatted Descriptions listing equally valid options as is the case here are indicated by bullet points Descriptions that describe performing a function are shown in the form of numerical lists indicating the ord...

Страница 6: ...box to check whether the wallbox has been approved to be installed and operated in your country The wallbox must be installed connected and approved for operation according to local rules and regulations by a qualified specialist electrical contractor The wallbox does not contain a residual current circuit breaker RCCB It must be installed in the upstream power supply and exclusive to the supply c...

Страница 7: ...operation of the device Disregard of or actions contrary to the safety information and instructions contained in this manual may lead to electric shock fire severe injury and or death The Mercedes Benz Wallbox must be installed by a qualified specialist electrical contractor connected according to local regulations and norms and subsequently checked and approved for operation Malfunctions affectin...

Страница 8: ...the device comply with the parameters of your local electricity grid and that the rated output is not exceeded during the charging procedure The wallbox should not be installed in areas of high pedestrian traffic Installation along thoroughfares and marked escape routes should be especially avoided Never install the wallbox in a confined space In particular you must ensure that the vehicle can be ...

Страница 9: ...arging process must be separately authorized via the integrated key switch Unpacking and components included The Mercedes Benz Wallbox package includes a range of accessory components needed for installation and proper operation Therefore please check immediately after unpacking together with the customer if required whether the following compo nents are included Component Quantity Description Wal...

Страница 10: ...the installation site Your Mercedes Benz Wallbox is an electrical device and is therefore subject to particular requirements for indoor and outdoor installation In selecting the installation site you must consider the following points Consider all local regulations for electrical installations fire protection and accident prevention The wallbox must be installed where it is freely accessible to al...

Страница 11: ...ar The power supply for the wallbox must always be protected by its own MCB and RCCB at least Type A Please always observe current national regulations regarding the selection of MCB and RCCB Depending on the country an RCCB with a different tripping characteristic e g Type B may be prescribed The wallbox does not have a dedicated ON OFF switch If you want to take the wallbox out of operation you ...

Страница 12: ...stallation Otherwise there is a risk of severe injury through electric shock or even death Proceed as follows to drill the holes using the mounting plate 1 Ensure that a sufficiently dimensioned power supply is available at the desired installation site Otherwise a power supply must be installed especially 2 The mounting plate has pre molded cable inlets for the power supply on its upper edge as w...

Страница 13: ... PLEASE NOTE The strain relief is not required if the power supply enters from the rear 83 7 Now open the housing cover of the wallbox using the triangular key sup plied and flip it towards the front PLEASE NOTE Take special care with this and protect the housing cover against scratching and other external damage If possible only remove the protective film from the housing cover just before comple...

Страница 14: ...he mounting plate 12 If using a power supply with flexible wires ensure that the stripped ends are fitted with wire end ferrules Loosen the lower screws in the terminal blocks insert the wires into their respective terminal and tighten with a torque of 2 5 to 3 Nm The wiring sequence is shown in the following diagram and table The supply cable for the single phase model variant A0009060307 is conn...

Страница 15: ...dingly before you replace the electronic components cover and then take the wallbox into operation This is described in detail in section Setup and testing modes on page 16 and following Please note that the rated current indicated on the product label and configured in the firmware must under no circum stances be exceeded 13 Replace the electronic components cover inside the housing and fix it wi...

Страница 16: ...he firmware only relevant for error detec tion On completion the blue LED flashes every 5 seconds the green LED and the red LED go out The vehicle can now be connected for charging The charging procedure itself is described in the operating manual included PLEASE NOTE To complete electrical installation the protective devices of the wallbox must be checked in testing mode for correct func tioning ...

Страница 17: ...view of country specific mains connection schemes on page 26 in this manual or on the www yourwallbox de website using the following link www yourwallbox de Mains_Connection_Schemes If necessary please change your mains connection scheme according to this overview An internal fault has occurred in the wallbox The wallbox must be replaced In this case please always contact your local Mercedes Benz ...

Страница 18: ...the red LED is continuously ON Solution If the error occurs for the first time the charging procedure is interrupted for 30 seconds and then restarted automatically If the error occurs again immediately the charging procedure is terminated a new charging procedure is only possible after disconnecting the vehicle from the wallbox There is possibly an electrical fault in the charging system of the v...

Страница 19: ... 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description Error F10 The temperature monitor has detected a tem perature above 80 Celsius inside the housing The green LED flashes four times the blue LED also flashes every third and fourth time and the red LED is continuously ON Solution The temperature monitor interrupts the charging procedure After 10 minutes the charging procedure is automatically r...

Страница 20: ...e internal rotary encoders However the rated current indicated on the product label must not be exceeded under any circumstances Setup mode To make adjustments via the rotary encoder you must first remove the internal electronic components cover of the wallbox This is described in steps 7 and 8 page 9 of section Mechanical installation of the mounting plate DANGER After opening the cover for the e...

Страница 21: ...er approx 10 seconds all LEDs will be on 5 Switch off the power supply via the up stream MCB s and RCCB 6 Remove the internal electronic compo nents cover Set the S1 rotary encoder to the 0 1 or F position Ensure that the S3 rotary encoder remains set to the 0 position 7 Replace the internal electronic compo nents cover Close and lock the housing cover Switch the power supply back on via the upstr...

Страница 22: ...sing extreme cau tion Otherwise there is a risk of severe injury through electric shock or even death 5 With the wallbox in testing mode you can now measure the voltage at each phase of the charging socket charging connector Measuring the signal at the CP contact against PE the frequency as well as the duty cycle are also possible ca 10 minutes The flashing LEDs indicate that the wallbox is switch...

Страница 23: ... A 9 20 A A 30 A B 32 A C 64 A D Return to factory setting 16 A E Testing mode See position 2 F Normal operation Setting for normal charging operations The following settings can be selected using the S3 rotary encoder on the right 0 Normal operation Setting for normal and testing operations 1 0x01 When the S1 rotary encoder is set to position 3 see above you can allocate the wallbox a different d...

Страница 24: ...the start up procedure As described in section Taking the wallbox into operation on page 11 the vehicle can now be connected for charging Returning your wallbox Should your wallbox display error messages permanently during installation or subsequent operation or if it does not function properly contact your local Mercedes Benz technical support If the error can still not be resolved repairs must b...

Страница 25: ...trol Customization internal RS485 and USB interfaces no user installer access Operating temperature 30 C to 50 C Storage temperature 30 C to 85 C Relative humidity 5 to 95 no condensation Class of protection I Overvoltage category III Degree of pollution 3 Degree of protection housing IP54 Impact strength IK08 Dimensions incl mounting plate 492 x 400 x 194 mm H x W x D Dimensions w o mounting plat...

Страница 26: ...The Mercedes Benz Wallbox is delivered fully assembled and checked All dimensions as well as the mounting points are indicated in the scale drawings below Mounting plate Plan and elevation all dimensions in mm 200 254 83 477 9 32 376 4 ...

Страница 27: ...s Benz Wallbox Appendix Wallbox with fixed charging cable Plan and elevation all dimensions in mm Contact chart Type 1 Type 2 394 143 492 134 194 492 134 Type1 Type2 PP PE CP N L3 PP PE L1 L2 CP CS L2 N PE CP L1 ...

Страница 28: ...harging systems for electric vehicles Part 1 General requirements E DIN EN 61851 22 2011 04 Conductive charging systems for electric vehicles Part 22 AC charging station for electric vehicles HD 60364 7 722 2012 Low voltage installations Part 7 722 Power supply for electric vehicles Classes of protection Degrees of protection Class of protection Degree of protection Explanation The device complies...

Страница 29: ...ot represent any obligation on the part of the manufacturer Illustrations in this manual may show designs different from the delivered product and do not represent any obligation on the part of the manufacturer The manufacturer does not take responsibility for any loss and or damages that occur because of the data or possible misin formation contained in these instructions This manual in its entir...

Страница 30: ... 110 220 V L1 L2 x Eurasian Customs Union Belarus Kazakhstan Russia 50 Hz 230 400 V L1 L2 L3 N x French Polynesia Tahiti 60 Hz 220 V L1 N x Hong Kong 50 Hz 220 380 V L1 L2 L3 N x India 50 Hz 220 380 V L1 L2 L3 N x 230 400 V 240 415 V Indonesia 50 Hz 127 220 V L1 L2 x 220 380 V L1 L2 L3 N x Israel 50 Hz 230 400 V L1 L2 L3 N x Jamaica 50 Hz 110 220 V L1 L2 x Japan 50 60 Hz 200 V L1 L2 x Jordan 50 Hz...

Страница 31: ...1 N x Sri Lanka 50 Hz 230 400 V L1 L2 L3 N x Taiwan 60 Hz 110 220 V L1 L2 x 220 440 V L1 N x Thailand 50 Hz 220 380 V L1 L2 L3 N x Ukraine 50 Hz 230 400 V L1 L2 L3 N x United Arab Emirates 50 Hz 220 380 V L1 L2 L3 N x 240 415 V Vietnam 50 Hz 127 220 V L1 L2 x 220 380 V L1 L2 L3 N x Region Country Local frequency Local voltage domestic applications Phase L1 Phase L2 Phase L3 Neutral 1 ph 3 ph Europ...

Страница 32: ...ations to the product after publication of this instruction manual This may also have led to minor discrepancies in the appearance of the product Any color differences are a result of the printing process Daimler AG Mercedesstr 137 70327 Stuttgart Germany ...

Отзывы: