7
Mercedes-Benz Wallbox
| Preparations, installation and taking into operation
•
The wallbox meets the requirements for outdoor installation. Outdoors, the wallbox should only be installed in covered loca-
tions that provide sufficient protection from weather-related pollution.
Requirements for the power supply
The following standards must always be considered for the electrical installation of the Mercedes-Benz Wallbox:
•
All regulatory requirements for low voltage installations according to IEC 60364-1 and IEC 60364-5-52 apply.
•
Model variant A0009060307 is intended for the rated voltage indicated on the product label.
•
The installation site must offer a sufficiently dimensioned power supply according to HD 60364-7-722:2012 (see also
“Guidelines & Norms” on page 24): This power supply must be reserved exclusively for the wallbox and must not be used
to supply other electrical devices.
•
If necessary, a separate power supply must be installed that is intended exclusively for connecting the wallbox and com-
plies with the general requirements for cabling and building infrastructure.
•
Depending on the desired rated power, the installation of the wallbox may need to be registered with and/or approved by
the local electricity grid operator. Please consult the local regulations of your electricity grid operator.
•
Cable dimensions must be adjusted according to the desired rated power and other aspects (such as cable length, mate-
rial, cabling method etc.). The terminal blocks in the wallbox are designed for cable dimensions of up to 16 mm
2
.
•
The power supply cables may be installed above or below the wall surface: The mounting plate provides alternative cable
inlets at the top and at the rear.
•
The power supply for the wallbox must always be protected by its own MCB and RCCB (at least Type A): Please always
observe current national regulations regarding the selection of MCB and RCCB. Depending on the country, an RCCB with a
different tripping characteristic (e.g. Type B) may be prescribed.
•
The wallbox does not have a dedicated ON/OFF switch: If you want to take the wallbox out of operation, you must always
switch the upstream domestic MCB(s) and RCCB to the 0 (OFF) position.
•
Please always ensure that the installation requirements listed in this manual are complied with. Disregard or actions to
the contrary may lead to severe injury by electric shock or even death. In addition, in case of contravention of the notices
given, the proper operation of the wallbox cannot be guaranteed.
PLEASE NOTE!
In some countries, the above mentioned requirements are different from the prerequisites for connecting to the local
power grid. In this case, the wallbox must be connected in accordance with the respective type of mains power connec-
tion for the country of installation. You can find an overview of country-specific mains connection schemes on page 26
in this manual or on the
www.yourwallbox.de
website using the following link:
www.yourwallbox.de/Mains_Connection_Schemes
Mechanical installation of the mounting plate
After determining the mounting site for the wallbox, you can begin with mechanical installation. For installation you will need
the following components:
•
Power drill or cordless drill (not included)
•
Drill bit Ø 10 mm, appropriate for the wall substrate (not included)
•
Screwdriver with flat head (2.5 mm blade width), Phillips head (PH1) and torx head (TX40, TX25, TX20, TX10) bits
•
Mounting plate (included)
•
Pliers or cutter for breaking or cutting out the cable inlet in the mounting plate (not included)
•
Four 8 x 60 wafer head (TX40 bit) screws for fixing the mounting plate (included)