85-03-01154
FV36 DÉCOR
Page
13
3.2
MECHANICAL TECHNICAL REFERENCES
Planning the installation
This Mendota Fireplace must be installed and serviced by a qualified installer, service agency, or the gas supplier.
When planning on appliance installation, it is necessary to determine the following information before installing:
•
Where the appliance is to be installed.
•
The vent system configuration to be used.
•
Gas supply piping.
•
Electrical Wiring.
•
Framing and finishing details.
•
Hearth Protection Pad Requirements.
•
Whether accessories such as a ceiling fan are desired.
Selecting Appliance Location
When selecting a location for your appliance, it is important to consider the required clearances to walls.
Figure 3-1 FIREPLACE LOCATION
WARNING
FIRE RISK- ODOR RISK
•
Install appliance on hard metal or wood surfaces extending full width and depth of this fireplace.
•
An R-1 Rated Hearth Protection Pad [1-
1/2” Thick Maximum] is required unless this fireplace is elevated. For
every 1” this fireplace is elevated, you may reduce the hearth pad depth by 2”. If this fireplace is elevated 6”
or higher no hearth protection pad is required.
•
Do NOT install this fireplace directly on carpeting, vinyl or any combustible material other than wood.
Construct chase to all clearance specifications in manual.
•
Locate and install appliance to all clearance specifications in manual.
Содержание AA-11-04109
Страница 2: ...85 03 01154 FV36 D COR...
Страница 16: ...85 03 01154 FV36 D COR Page 16 Figure 3 11 Figure 3 10...
Страница 24: ...85 03 01154 FV36 D COR Page 24 Clearance from Appliance Side Walls Figure 3 17 CLEARANCE TO BODY...
Страница 87: ...85 03 01154 FV36 D COR Page 87 Gas Train Assembly Parts Figure 5 5 Gas Train Assembly Parts...
Страница 88: ...85 03 01154 FV36 D COR Page 88 Burner Figure 5 6 Burner...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...