3.2.17.3.3
FlexHeat
The FlexHeat system uses two inline fans to redirect heat from the fireplace outside the home or to an alternate room in the
home.
WARNING:
To reduce temperatures above the fireplace for mounting a television the FlexHeat system must always be on when
the fireplace is in operation. Because the FLexHeat system must be running to reduce temperatures the fireplace cannot be
operated during a power outage.
Testing has shown that when using the FlexHeat system temperatures above the fireplace are reduced making it possible to
mount a television 12” above the fireplace’s top air gap.
Venting
The FV36 DÉCOR Fireplace must be vented to the outside and must use one of the approved coaxial rigid
ducting systems.
Do Not Use any silicone sealants at pipe joints. Stove gasket cements may be used
at pipe joints but is not required
.