85-03-01154
FV36 DÉCOR
Page
8
Safety Standards and Warnings
Do not operate this appliance with the glass removed, cracked or broken. Only glass doors certified with this
appliance shall be used.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this ap pliance and
must be installed. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's
barrier for this appliance.
Any Barrier Screen or guard removed for servicing must be replaced before operating fireplace.
Tout écran ou
protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de
mettre l’appareil en marche.
This unit is not for use with solid fuel.
Ne pas utiliser avec du combustible solide.
Installation and repair should be
performe
d by a qualified service person. The fireplace and venting system
should be
inspected
before initial use and at least annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpeting, bedding, material, etc. It is imperative that
the unit’s control compartment, burners and circulating air passageways are
kept clean
to provide for
adequate combustion and ventilation air.
L’installation et la réparation devrait être confiées à un technicien qualifié. L’ap pareil devrait faire l’objet
d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite.
Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une
quantité importante de poussière. Il est essentiel que les compartiments abritant les commandes, les
brûleurs et les conduits de circulation d’air de l’appareil soient tenus propres.
Always keep the fireplace clear and free from combustible materials, gasoline, and o ther flammable vapors
and liquids.
Never obstruct
the flow of combustion and ventilation air. Keep the front of the fireplace clear of all
obstacles and materials for servicing and proper operation. Use only Mendota approved Screens, Fronts and
Trim Kits.
Due to high temperature, the fireplace
should be located out of traffic areas
and away from furniture and
draperies. En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu
de circulation et loin du mobilier et de s tentures.
Clothing or flammable material should not be placed on or near the fireplace.
On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
Children and adults should be
alerted
to the hazards of high s urface temperature and should
stay away
to
avoid burns or clothing ignition. The door glass, surrounding walls and objects can be too hot to touch.
Les enfants et les adultes devraient être informés des dangers que posent les températures de surface
élevé
es et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
Young children should be
carefully supervised
when they are in the same room as the fireplace. Toddlers,
young children and others may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict access to a fireplace or stov e, install
an adjustable safety gate to keep toddlers, young children and other at -risk individuals out of the room and
away from hot surfaces. This physical barrier is in addition to the required glass barrier Screen.
Les jeunes enfants devraient être sur
veillés étroitement lorsqu’ils se trouvent dans la même pièce que
l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en
contact avec la surface chaude. Il est recommandé d’installer une barrière physiqu
e si des personnes à
risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de
sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque
d’avoir accès à la pièce et aux
surfaces chaudes.
These units
must
use one of the vent systems described in the Flue Venting section of this manual.
Содержание AA-11-04109
Страница 2: ...85 03 01154 FV36 D COR...
Страница 16: ...85 03 01154 FV36 D COR Page 16 Figure 3 11 Figure 3 10...
Страница 24: ...85 03 01154 FV36 D COR Page 24 Clearance from Appliance Side Walls Figure 3 17 CLEARANCE TO BODY...
Страница 87: ...85 03 01154 FV36 D COR Page 87 Gas Train Assembly Parts Figure 5 5 Gas Train Assembly Parts...
Страница 88: ...85 03 01154 FV36 D COR Page 88 Burner Figure 5 6 Burner...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...