4.8
First Time Lighting Instructions
Safety Information
•
This fireplace is equipped with an ignition device which automatically lights the pilot. Do not attempt to light pilot by hand.
•
Before operating
, smell all around fireplace area for gas. Be sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
•
Toggle Master Switch to
ON
. Remote control will not communicate to receiver unless the Master Switch is
ON
.
•
Use only the supplied remote control to light the pilot. This valve will not operate if the pilot is not lit and stable.
•
Do not use this fireplace if any part has been underwater. Immediately call a qualified service technician to inspect and replace
any component which has been under water. Attempted operation may result in fire or explosion resulting in property damage,
personal injury, and loss of life.
4.9
OPERATING INSTRUCTIONS
1.
Read the above safety information carefully before proceeding.
2.
Do not attempt to light the pilot by hand; the door must remain on this unit during pilot ignition, except for the “First Tim
e
Lighting”.
3.
Press the ON/OFF button on remote control to begin the ignition sequence.
4.
The fireplace will emit an audible beep then the igniter will begin to spark. After the pilot lights and is established, the valve will
automatically open and the burner will light. The burner will initially light to full flame. Adjust it to an appealing setting with the
remote. See Remote Operating Instructions in Operating Instructions Manual.
Warning:
If the pilot fails to light, the syst
em will “lockout”. Press ON/OFF button
on remote control to Turn Off the system
and reset the “lockout”
. Allow five minutes for any gas in the unit to dissipate before attempting to re-light the pilot.
5.
Press ON/OFF button on remote control again to start ignition sequence.
6.
If the fireplace
will not operate, follow the instructions “To Turn off Gas to
Fireplace
”
below and call your service technician or
gas supplier.
4.10
TO TURN OFF GAS TO FIREPLACE
1.
Press the ON/OFF button on the remote control.
2.
Turn off CPI Pilot Mode from remote control.
3.
Turn off the internal manual shutoff valve in the appliance. See 3.4.6 Factory Installed Manual Gas Shutoff Valve.
4.
Turn OFF the external manual shutoff valve if was required and supplied by installer and mounted adjacent to fireplace.
5.
Turn OFF all electric power to the fireplace if service is to be performed.
Warning: If you do not
follow these instructions
exactly, a fire or
explosion may result
causing property
damage, personal injury,
and loss of life.
WHAT TO DO IF YOU SMELL GAS
Do not light any appliance.
Do not touch any light switch
Do not use any phone in your building.
Call your gas supplier from a neighbor's phone.
Follow the provider representative's instructions.
If you cannot reach your gas supplier, call the fire
department for assistance.
Содержание AA-11-04109
Страница 2: ...85 03 01154 FV36 D COR...
Страница 16: ...85 03 01154 FV36 D COR Page 16 Figure 3 11 Figure 3 10...
Страница 24: ...85 03 01154 FV36 D COR Page 24 Clearance from Appliance Side Walls Figure 3 17 CLEARANCE TO BODY...
Страница 87: ...85 03 01154 FV36 D COR Page 87 Gas Train Assembly Parts Figure 5 5 Gas Train Assembly Parts...
Страница 88: ...85 03 01154 FV36 D COR Page 88 Burner Figure 5 6 Burner...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...