Production Area Design
1.
In the entire area, there should be some room to allow for inspection and cleaning when
manufacturing equipment is installed.
2.
When placing the machines, all connections must be closed so that there are no openings.
3.
The floor on which the machines are placed should be accessible from the point of view of the
cleaning operation or should be completely closed.
4. In cases where equipment passes through sections such as ceiling, floor, wall, sufficient floor
should be provided between equipment and wall for cleaning or machine should be mounted on
the wall not to permit any gap.
5.
Auxiliary equipment must be removable and can be reassembled to facilitate cleaning.
6.
Production base should be covered with hard, smooth, easy to clean and non-absorbent material.
7.
For insulation, non-absorbent materials should be used. These surfaces should be accessible.
8.
Stacking should be made on palettes to let minimum 100 mm distance with the floor when
storing the products.
9.
Vessels used to collect waste products and waste water should be made of easy to clean materials
and should have sufficient volume.
10. Doors and windows opening out of the plant should be isolated to prevent any outsourced
contamination.
11. Sufficient ventilation should be ensured in the washing rooms.
12. Water and water vapor that come into direct contact with the products should be of drinkable
quality.
13. Pipes, valves and fittings used for liquid materials: Either “on-site cleaning” programs should be
implemented for these sections or systems allowing easy disassembly and assembly should be
used.
14. All fixed pipes should be isolated to prevent condensation.
15. Drainage systems for wastewater must be installed in areas where cleaning is required.
16. Floor slope should be such as to prevent water accumulation on the surface.
17. Illumination lamps should be protected as to prevent falling and breaking.
18. Power cables should be stabilized (their contact with the ground should be prevented)
19. Machine’s electrical components should be closed to prevent dust formation. Water should be
prevented from entering electrical panels.
20. Machine parts such as fan, motor should be accessibly mounted.
21. Motor and other auxiliary equipment should be placed not to touch the floor.
Содержание STELLA COMBINE
Страница 1: ...INSTALLATION AND USER MANUAL FOR STELLA COMBINE OVEN I1...
Страница 2: ...2 I memak com 2 I memak com...
Страница 22: ...22 I memak com Waste Water Installation Waste water installation form shall conform to Figure 10 Figure10...
Страница 27: ...INSTALLATION AND USER MANUAL FOR STELLA COMBINE OVEN I27 TOUCH CONTROL PANEL SIGNALS...
Страница 62: ...62 I memak com Machine Mechanism Lubricating Figure9 Figure10...
Страница 67: ...INSTALLATION AND USER MANUAL FOR STELLA COMBINE OVEN I67...
Страница 68: ...68 I memak com...