InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
75
The manager also has the ability to burn new firmware and upgrade software on the
switch.
5.1
InfiniBand Subnet Manager
The InfiniBand Subnet Manager (SM) is a centralized entity running in the switch. It dis-
covers and configures all the InfiniBand fabric devices to enable traffic flow between
those devices. The SM applies network traffic related configurations such as QoS, rout-
ing, partitioning to the fabric devices.
You can view and configure the Subnet Parameters (SM) via the CLI/WebUI.
Each InfiniBand subnet needs one subnet manager to discover, activate and manage the
subnet. An InfiniBand® network requires a Subnet Manager to be running in either the
Infiniband switch itself (switch based) or on one of the nodes which is connected to the
Infiniband fabric (host based).
5.2
Fabric Inspector (Diagnostics)
Fabric Inspector is a plug & play software for fee within MLNX-OS displaying and fil-
tering all identified systems and nodes within the fabric.
Fabric Inspector includes a complete set of tools for fabric wide diagnostics to check
node-node and node-switch connectivity and to verify routes within the fabric.
Advanced filtering allows creating filtering rules on a system wide basis, between nodes
or port connections based on traffic patterns and user assigned system names (GUIDs).
5.3
Accessing the CPU via the Ethernet Connector
Once the initial configuration is completed the management tools can be accessed
through:
•
SSH
•
Telnet
•
WEB
•
SNMP
•
XML
5.4
Upgrading Software
The new software and firmware updates are available to the user from the Mellanox Sup-
port website. Copy the update to a known location on a Remote server within your LAN.
Use the CLI or the GUI in order to perform the Software upgrade. For further informa-
tion please refer to the MLNX-OS user manual.
If
MLNX-OS
is updated and the FW image in the leafs and spines of the chassis is an
earlier version than the minimum that the new version of the software can work with,
then the chassis management system may require up to ~45 minutes to update all of the
FW images in all of the leafs and spines.
Содержание MSX6512-4R
Страница 96: ...Rev 2 2 Mellanox Technologies 96 5 6 7 8 9 10...
Страница 97: ...Rev 1 3 Mellanox Technologies 97 11 12 13 14 15 16...
Страница 98: ...Rev 2 2 Mellanox Technologies 98 17 18 19 20 21 WEEE 22...
Страница 100: ...Rev 2 2 Mellanox Technologies 100 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Страница 113: ...Rev 1 3 Mellanox Technologies 113 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...
Страница 114: ...Rev 2 2 Mellanox Technologies 114 11 12 13 14 15 16 UL CSA UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...