InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
70
3.4.1
I2C
3.4.2
CONSOLE
The CONSOLE port is used during the installation process to configure the chassis for
remote management. Connect this port to a local host using the harness supplied with the
chassis. See the Installation Guide for the initial configuration procedure.
3.4.3
MGT– Management
The MGT port is an Ethernet port for remote management. Any remote terminal con-
nected to the Ethernet port can then be used to manage the fabric and chassis.
3.4.4
USB
The USB port can be used to upload new SW using any storage device that has a USB
connector. This interface is USB 2.0.
3.4.5
Reset – RST
The Reset button resets the chassis management module when the button is pushed.
When the button is held down for 15 seconds the management module is reset and the
password deleted.
This interface is for Debug and Troubleshooting only.
This interface is for FAEs
only.
Each Ethernet connector gets connected to Ethernet switches. These switches must be
configured to 100M/1G auto-negotiation.
Initial configuration must be done on all of the management modules. The first man-
agement module you configure will be the master.
DO NOT use a sharp pointed object such as needle or push pin for pressing the Reset
button. Sharp objects can cause damage, use a flat object such as a paper clip.
Содержание MSX6512-4R
Страница 96: ...Rev 2 2 Mellanox Technologies 96 5 6 7 8 9 10...
Страница 97: ...Rev 1 3 Mellanox Technologies 97 11 12 13 14 15 16...
Страница 98: ...Rev 2 2 Mellanox Technologies 98 17 18 19 20 21 WEEE 22...
Страница 100: ...Rev 2 2 Mellanox Technologies 100 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Страница 113: ...Rev 1 3 Mellanox Technologies 113 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...
Страница 114: ...Rev 2 2 Mellanox Technologies 114 11 12 13 14 15 16 UL CSA UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...