InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
48
3. Check back signal connectors’ integrity. Look for any broken signal dividers or any
deviations from the pass criterion shown in Figure 34.
Figure 34: Intact vs Defected Signal Connectors
4. Check power connector’s integrity. Look for any damage on the power connector
casing or blades damage, or any deviations from the pass criterion show in Figure 35.
Figure 35: Intact vs Defected Power Pin Holders
5. Start with the ejector handle fully open; that is, at 45 degrees to the front panel of the
leaf.
6. Holding the leaf by its sides, carefully set the leaf board into the chassis.
Pass
Fail
Pass
Fail