PISTON ADHESIVE MELTER
MELTER OPERATION
4-27
Flowmeter
Optionally, the unit can come equipped with an adhesive flow control system
with the following functions:
• Immediate measurement of adhesive consumption by time and by product
(<5% error).
• Configuration of 5 products with editable names.
• Programmable alarm for consumption that exceeds programmed limits.
• Target consumption by product.
• Automatic learning of target consumption by product.
• Automatic adjustment based on the pattern being used and the working
speed.
• Automatic adjustment of the system when the working pressure changes.
• Automatic or manual system calibration.
• Automatic calculation of the adhesive density.
• Flow adjustment by manually entering a value into the correction field.
• Selector of programmed products from the start screen.
• Total statistics and statistics for each product.
System calibration
This function can be activated or disabled via the ‘2. Additional set-up / 2.2
Additional settings’ screen. To calibrate the system, press the right arrow in
the Flowmeter option.
Calibration must be done when:
• The unit is programmed for its first use.
• The type of adhesive is changed.
• The working temperature is changed.
• Accuracy losses are noticed.
• Regularly (3-4 weeks), for jobs with low adhesive consumption.
Important:
During calibration, the unit must be at the working pressure and
temperature.
1. Enter the unit’s hydraulic pressure.
2. Press ‘Play’ in ‘Calibration’ and the unit will automatically do the
calculations. Depending on the programmed pressure and temperature
and the adhesive type, the time could be up to a maximum of 1 hour.
3. When the calculation is completed, it will show ‘Ready’ next to the ‘Play’
button. The ‘Adjustment’ section will show the calculated value. The value
will be between 30 and 1000, depending on the viscosity of the adhesive,
the temperature, and the working pressure.
4. Press ‘Save’ once the process is completed.
PISTÓN
HMI
: S02001101 v1.1.2
TC
: S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
6
2.2 Extra Settings
Regrind charger
Channel number
Feeder
Pattern controller
Level detector
Extermal HMI
Wireless communication
Bluetooth
Flowmeter
PISTÓN
HMI
: S02001101 v1.1.2
TC
: S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
70
bar
Play
st/10h
Play
g
g/cm3
7cc Pump
Flowmeter
Product Configuration
Pressure
Calibration
Adjustment
Density calculation
Weight
Density
1
3
2
4
!
Содержание Micron + 10
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 90: ...FOCKE MELER GLUING SOLUTIONS 6 6 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Страница 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 97: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER PNEUMATIC DIAGRAM 8 5 Pneumatic diagram for 19 cm3 stroke PUMP ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Страница 104: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...
Страница 118: ...This page is intentionally left blank ...