FOCKE MELER GLUING SOLUTIONS
4-16
MELTER OPERATION
(*) Example values
PISTÓN
HMI
: S02001101 v1.1.2
TC
: S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
40 °C
200 °C
10 °C
60 s
20 °C
60 s
230 °C
10 s
10 min
60 s
10 °C
20 °C
1.5 Heating Extra Settings
Programmable limits
min
max
Temprerature warning (+/-)
Temperature alarm in zone (+/-)
Total alarm due to temperature
Pumping permission delay
Adaptative time
1.5 Heating Extra settings
• Pumping permission delay:
This is the time that the unit must wait to
activate pumping after all the active zones have reached a temperature
above [Set point temp. -3°].
• Programmable limits:
Two limits can be set to prevent set point
temperatures from being programmed above or below those values.
• Temperature warning:
A temperate (±°C/°F) and a time are defined to
indicate when the overheating or low temperature warning is activated in
each zone.
• Temperature alarm:
A temperature (±°C/°F) and a time are defined to
indicate when the overheating or low temperature alarm is activated in
each zone.
If either of those values are reached (±) and maintained for the set time,
the unit disconnects the heating in the zone causing the error. If the error
persists 3 minutes later, the remainder of the zones are automatically
disconnected. If the affected zones are the tank or the distributor, the unit
also stops the pumping.
• Total temperature alarm:
A temperature (±°C/°F) and a time are defined
to indicate when the overheating alarm is activated. If any zone reaches
this temperature and maintains it for the set time, the unit disconnects
the heating of all zones and stops the pumping.
• Adaptive time:
Automatic interval setting for warning and alarm
temperatures, when the user reprogrammes the setpoint values.
Status
Actual
temperature*
Set point
emperature*
Heating
Pumping
OUTPUTS
Temp.OK
zones
Alarm
Activated
Ready /
Running
150
150
ON
ON
ON
OFF
ON / OFF
140
150
ON
ON
ON
ON
ON / OFF
160
130
150
OFF
Unit
OFF when...
Error in Tank
Error in Distributor
OFF
ON
ON/OFF
170
OFF
Zone in error
ON when...
Error in the remainder
of the Zones
OFF when...
3’ in error
190
150
OFF
All Zones
OFF
OFF
ON
OFF
Содержание Micron + 10
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 90: ...FOCKE MELER GLUING SOLUTIONS 6 6 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Страница 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 97: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER PNEUMATIC DIAGRAM 8 5 Pneumatic diagram for 19 cm3 stroke PUMP ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Страница 104: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...
Страница 118: ...This page is intentionally left blank ...