MA-5162-ENG
PISTON ADHESIVE MELTER
INSTALLATION
3-13
Wireless connection (Wi-Fi)
Optionally, the unit comes equipped with a wireless connection module (Wi-Fi)
to connect to a local network.
To activate and configure this function, see chapter ‘4. Use’.
Connecting product passage signal (Flowmeter)
Attention:
it is recommended that all input/output cables are shielded.
In the melting equipment, the shield must be connected outside, in the
equipment chassis or in the connector prepared for this purpose in
some models.
Warning:
Risk of electric shock. Carelessness may cause injuries or death.
1. Disconnect the unit’s power.
2. Open the front door of the electric cabinet by giving the fastening screw
a 1/4 turn.
3. Run the signal cable (max. Ø14 mm) through the bushing at the rear of
the unit (P) and attach it to the interior fitting, making sure the cable
reaches the corresponding terminal (X).
4. Connect the three cable wires to the corresponding terminal. The
polarity of the connection must be correct:
5. Make sure that the cables are properly secured by the terminal’s
screws.
6. Check that the cable is correctly connected and that its passage
through the electric cabinet presents no risk of jamming, being cut or
any other accidental damage.
7. To assign the function to be performed by the connected signal, see
point ‘4 Use /Flowmeter’.
Terminal
Polarity
FC Color
X0V
0V
BLU
XIN
IN
BLK
X24V
+24 VDC 400mA
BRN / PNK
X
P
Содержание Micron + 10
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 90: ...FOCKE MELER GLUING SOLUTIONS 6 6 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Страница 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 97: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER PNEUMATIC DIAGRAM 8 5 Pneumatic diagram for 19 cm3 stroke PUMP ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Страница 104: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...
Страница 118: ...This page is intentionally left blank ...