
MA-5162-ENG
PISTON ADHESIVE MELTER
INSTALLATION
3-9
Connecting external inputs and outputs
Attention:
it is recommended that all input/output cables are
shielded. In the melting equipment, the shield must be connected
outside, in the equipment chassis or in the connector prepared for
this purpose in some models.
Warning:
Risk of electric shock. Carelessness may cause injuries or death.
1. Disconnect the unit’s power.
2. Open the front door of the electric cabinet by giving the fastening
screw a 1/4 turn.
3. Run the signal cable (max. Ø14 mm) through the bushing at the rear
of the unit (P) and attach it to the interior fitting, making sure the
cable reaches the corresponding terminals/connectors.
4. Connect the two cable wires to the corresponding terminal/
connector. The polarity of the connection must be correct:
5. Make sure that the cables are properly secured by the terminal’s
screws.
6. Check that the cable is correctly connected and that its passage
through the electric cabinet presents no risk of jamming, being cut
or any other accidental damage.
7. To assign the function to be performed by the connected signal, see
point ‘4 Use / Settings Menu / Configuration of input and output
signals’’.
Terminal
Polarity
Connector
Polarity
XDI 1.1
+24 VDC 200mA
DI3 1
+24 VDC 200mA
XDI 1.2
IN
DI3 2
IN
XDI 2.1
+24 VDC 200mA
DO2 1
+24 VDC 2A
XDI 2.2
IN
DO2 2
GND
XDO 3.1
+24 VDC 100mA
XDO 3.2
OUT
XDO 4.1
+24 VDC 100mA
XDO 4.2
OUT
P
DI3
DO2
Содержание Micron + 10
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 38: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 16 This page is intentionally left blank ...
Страница 74: ...FOCKE MELER GLUING SOLUTIONS 4 36 MELTER OPERATION This page is intentionally left blank ...
Страница 84: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 90: ...FOCKE MELER GLUING SOLUTIONS 6 6 TECHNICAL CHARACTERISTICS This page is intentionally left blank ...
Страница 91: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER ELECTRICAL DRAWINGS 7 1 7 ELECTRICAL DRAWINGS ...
Страница 92: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 97: ...MA 5162 ENG MICRON PISTON ADHESIVE MELTER PNEUMATIC DIAGRAM 8 5 Pneumatic diagram for 19 cm3 stroke PUMP ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 10 PNEUMATIC DIAGRAM This page is intentionally left blank ...
Страница 104: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...
Страница 118: ...This page is intentionally left blank ...