Instructions Manual
(6) Step angle switch input(C.S)
① Operating current range : 4.0mA~5.3mA
The photo-coupler turns on with
inter-terminal voltage of 19.1 V~25.1 V.
(Photo-coupler diode V
F
≒ 1.1 V)
● Step angle division is switched to 1/20 divisions with the photo-coupler ON.
The setting for the STEP ANGLE SELECT switch is ignored.
●No displacement occurs even if the step angle is switched by the C.S signal.
② Timing chart
Number of divisions
1/20divisions
Number of divisions
of STEP SEL switch
of STEP SEL switch
ON
OFF
C.S
t1≧30ms
t2≧ 1ms
● Switching the step angle by the C.S signal requires time "t1" and "t2" before
and after inputting drive pulse.
③ STEP ANGLE SELECT switch and C.S signal
〔STEP ANGLE SELECT switch〕
〔When the C.S signal is input〕
1/20 divisions
(0.036°)
1
2
1/2
1/4
1/10
0.072
9
1/20
1/40
1/100
5
6
7
1/200
8
0.0009
1/400
1/800
0.36
0.0018
0.18
0.0036
0.018
0.0072
0.036
3
4
t2
0
1/1
Step angle(°)
0.72°Motor
0.72
Number of
Divisions
Switch No.
CWP
CCWP
t1
t2
t1