Instructions Manual
4.Function Set-up by Use
4-1.Setting MOTOR SELECT switch
Erroneous setting may cause burn on the
skin due to overheating of the motor.
Ensure correct setting.
The MOTOR SEL switch is turned to the setting
corresponding to the motor in use.
Set this switch with power OFF.
The switch is factory-set to [10L].
(1) Turn power [OFF].
(2) Turn switch1 [10L/5L] to the setting specified in the table
"10-4. Applicable Motors."
4-2.Setting STEP ANGLE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
The step angle is set up with the STEP SEL switch.
The step angle can be selected from ten different
types of step angles.
The switch is factory-set to [No.1].
(2)
Set the switch No. to the step angle required.
●Relationship between the STEP SEL switch No. and the step angle.
(Factory setting)
●Drive with two types of step angles are provided by combining
the STEP SEL switch setting and the C.S signal.
0.18
0.072
0.0018
0.0009
0.036
0.018
0.0072
0.0036
6
7
Switch
No.
1
2
3
4
0
8
9
Number of
Divisions
1/1
1/2
1/4
1/10
1/20
1/40
5
1/100
1/200
1/400
1/800
Step angle(°)
0.72°motor
0.72
0.36
I
I
-14-