Instructions Manual
10.Specifications
R1
10-1.General Specifications
DC+24V
*1 (Ripple voltage P-P 2.0V or less)
● Rated input current :
〔DRIVE I.SEL ⇒ No.F set up〕
at DRIVE
DC+24V: 1.5A
*2
● Rated input current :
〔HOLD I.ADJ ⇒ Approx. 40% set up〕
at HOLD
DC+24V: 0.3A
●DRIVE CURRENT
0.15A/phase~0.375A/phase
●HOLD CURRENT
Approx. 40% of DRIVE CURRENT
(factory-set)
●DRIVE CURRENT
0.30A/phase~0.75A/phase
●HOLD CURRENT
Approx. 40% of DRIVE CURRENT
(factory-set)
●Drive pulse input
(CW, CCW)
Photo-coupler input
●Motor excitation stop input
(M.F)
Photo-coupler input
●Step angle switch input
(C.S)
Photo-coupler input
●Phase signal output
(P.O)
O/C output
●Overheat alarm output
(O.H.A)
O/C output
●Motor selection
(MOTOR SEL)
●HOLD CURRENT adjustment
(HOLD I.ADJ)
●DRIVE CURRENT selection
(DRIVE I.SEL)
●Step angle selection
(STEP SEL)
●HOLD switching time selection
(DHT SEL)
Indoor (Exposure to direct sun is not allowed.)
Without any corrosive or inflammable gas, oil mist, or dust.
*1
Input voltage range is DC+24V±10%.
*2
Use a power supply that provides sufficient input current.
MOTOR SEL switch
is set to 〔5L〕
MOTOR SEL switch
is set to
〔10L〕
Functions of
Operating Sections
Operating Ambient
Temperature
(No freezing allowed.)
(No condensation allowed.)
0℃ ~ +40℃
80%RH or less
Operating Ambient
Humidity
-10℃ ~ +55℃
H
80 ×
W
90 ×
D
32 (mm)
0.2 kg
DC connector - signal connector - Frame
(Each other)
DC500V 100MΩ or more
80%RH or less
(No condensation allowed.)
No abnormality should be found after a vibration test
at 10~55Hz, 0.15mm P-P
(No freezing allowed.)
Supply Power
Motor output
current
Input Signal
Output Signal
Insulation resistance
Exterior Dimensions
Weight
Storing Temperature
Storing Humidity
Atmosphere
Withstanding
Vibration
-28-