29 / 32
9648649
Service step
Maintenance work
Cleaning /
Maintenance
work
Daily
at least once
every quarter
at least once
every six
months
but
every
1000
hrs
at least once
every year
but
every 2000
hrs
5. Drying
Fan
Check the blower fan for exterior damage
Check current consumption (see electric wiring diagram)
Check fan for quiet running (bearing damage) (visual and noise check)
Check suction side grid for cleanliness
Heating register (steam or hot water)
Check the heating register for cleanliness
Clean damper register with hot water
Check the heating register for leaks (heating media)
Blowing box
Check nozzles for damage.
Extraction
Check extraction fan for exterior damage
Check the motor for bearing noise (check for bearing damage)
6. Rocker
Check the linear drive
Check the linear drive motor for external damage
Check the linear drive motor for bearing noises
Check current consumption (see electric wiring diagram)
Check drive chain
Check the chain, sprocket wheel and fixings for wear
Check chain tension
Check the locking bolt
Sealing for the leaf door
Check sealing pad for function
Check springs for tensioning force