Service Instructions Dishwashing Machine Model K-Tronic
Ident No.: 9627429
Page 23/30
Info
No.
Display
Note / Possible causes
Possible measures
14
Rinse agent
changed
Only manual entry possible
(Operation diary)
15
Detergent
changed
Only manual entry possible
(Operation diary)
General information
110
Maintenance needed
Maintenance is needed
After maintenance being
carried out the maintenance
counter must be reset on
configuration level
(parameter P101)
111
Door open
Close door
Door switch (reed contact) incorrectly set
or defective; cable broken, contact on
door switch;
Input to the I/O circuit board defective
112
Password wrong
Entry code not available in internal table
Correct entry code
113
Setting parameters
activated
The power supply must be interrupted to
release the factory setting parameters
(switch off main electrical power switch)
P130, P220 or P327 activated
114
EEPROM emerg.setting
Emergency strategy EEPROM problems
active, i.e. the device can also be
operated without an EEPROM in certain
circumstances
Supply EEPROM with data via
replacement parts service and
put on CPU2
115
EEPROM was empty.
Re-initialise
EEPROM was empty or incomplete ->
Data was been copied from the internal
EEPROM to the plug-in EEPROM
Message is automatically deactivated on
program (only devised as information, as
the complete extent of the program is not
available)
Supply EEPROM with data via
replacement parts service and
put on CPU2
Transfer parameter set by
M-Commander again
117
High Limit Switch
temp. exceeded
Safety temperature monitoring for
heating element indicates alarm
Lighting for heating defective.
Ascertaining the cause
(heating circuit) and possible
component replacement
118
Battery empty
If a voltage interruption occurs, the date
and time are not defined
Replace battery
119
Err. real time clock
Error with real-time on CPU2
Date and time cannot be used
Replace CPU2
Wash tanks
210
Temperature in pre-
wash too high
Actual temperature in the NDV too high
(maximum exceeded))
Setpoint temperature too low;
No water feed.
211
Tank temperature not
reached
Tank temperature not reached at the
right time
Tank heating element defective;
Contactor defective;
STP has triggered
212
Tank temperature
too high
Actual temperature in tank too high
Contactor sticking; temperature sensor
defective;
Plug contact temperature sensor with
high resistance
213
Tank temperature
sensor shortcut
Short circuit tank temperature sensor.
Short circuit in the wiring; damp in the
connector.
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
valid from: 2005-09-01
Update: 2006-11-14 / S.5
W e reserve the right to change execution and construction!