Service Instructions Dishwashing Machine Model K-Tronic
Ident No.: 9627429
Page 22/30
Err.
No.
Display
Note / Possible causes
Possible measures
CAN communication
801
Communication with
CAN-bus address 1
Communication cable not connected;
CAN address switch wrongly set.
No power supply to I/O circuit board;
I/O circuit board defective.
Connect.
Settings as in the circuit
diagram
Ensure power available
Replace I/O circuit board
Switch main switch off and
back on
802
Communication with
CAN-bus address 2
See above
803
Communication with
CAN-bus address 3
See above
804
Communication with
CAN-bus address 4
See above
805
Communication with
CAN-bus address 5
See above
806
Communication with
CAN-bus address 6
See above
807
Communication with
CAN-bus address 7
See above
808
809
Undefined bus address
recognized
Undefined bus users recognized
(CAN address switch wrongly set).
Check address switch;
correct parameter set
900
No I/O type defined
Wrong parameterization
(P310,311,..,323=0)
Correct parameter set
901
IO type on bus addr.1
incompatible
Wrong I/O type (P310) with CAN addr. 1
Faults through light sources with infrared
component
-> deactivate the infrared communication
via P129 for testing
Check I/O type;
Correct parameter set
902
IO type on bus addr.2
incompatible
Wrong I/O type (P311) with CAN addr. 2
Check I/O type;
Correct parameter set
903
IO type on bus addr.3
incompatible
Wrong I/O type (P312) with CAN addr. 3
Check I/O type;
Correct parameter set
904
IO type on bus addr.4
incompatible
Wrong I/O type (P313) with CAN addr. 4
Check I/O type;
Correct parameter set
905
IO type on bus addr.5
incompatible
Wrong I/O type (P314) with CAN addr. 5
Check I/O type;
Correct parameter set
906
IO type on bus addr.6
incompatible
Wrong I/O type (P315) with CAN addr. 6
Check I/O type;
Correct parameter set
907
IO type on bus addr.7
incompatible
Wrong I/O type (P316) with CAN addr. 7
Check I/O type;
Correct parameter set
8.2 Error indication, restricted wash process possible
Info
No.
Display
Note / Possible causes
Possible measures
System
10
Only manual entry possible
(Operation diary)
Water change
completed
11
Basic cleaning
completed
Only manual entry possible
(Operation diary)
12
Repair OK
Only manual entry possible
(Operation diary)
13
Maintenance OK
Automatic entry on reset of maintenance
counter
(see parameter P101)
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
valid from: 2005-09-01
Update: 2006-11-14 / S.5
W e reserve the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174