Operating instructions dishwashing machine model
K-Tronic
Datei:2K_9626212_Betriebsanleitung-MIKE_EN_2005-12-01.doc
gültig ab: 2003-01
Update: 2004-05-07
Ident-Nr.:
9619165
29/38
W e reserve the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: 0781/203-0, Fax: 0781/203-1174
Service step
c
d
e
f
Maintenance
Cleaning works
Daily
At least once
quarterly
At least once
or twice a
year
but
every
1000 h
At least once
yearly
but
every
2000 h
VERY IMPORTANT:
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
3. Wash systems
Check ascending pipe for watertightness
- Pump / ascending pipe connection
- Ascending pipe
- Ascending pipe / wash system connection
- Wash system seating
Check wash system
Check wash system for damage
Check nozzles for cleanliness
Check that the correct number of wash pipe end caps is present
Check the spray pattern (the whole width of the belt must be covered by
the spray).
The pressure from the lower spray must be controlled so that the lightest
dish does not rotate
4. Clean water rinse system
Check motor power switch (if present)
Check motor for exterior damage
Check current consumption
(
I
N
see wiring diagram)
Check motor for quiet running (bearing damage)
Check ventilation grid for cleanliness
Check pump power switch (if present)
Check sliding ring seal for watertightness (external visual check)
Replace sliding ring seal
Approx. every
2 years
Approx. every 3000 h
Check pump impeller for damage
Check pump housing for damage
System
Check the complete system for damage and watertightness
Check nozzles for cleanliness
Check water quantity (use the water meter or measure manually)
Clean the inlet tank
Check float switch function