Service Instructions Dishwashing Machine Model K-Tronic
Ident No.: 9627429
Page 24/30
Info
No.
Display
Note / Possible causes
Possible measures
214
Tank temperature
sensor break
Cable to tank temperature sensor
broken.
Connector incorrectly connected;
crimp connection inadequate
215
Pre-wash temperature
sensor shortcut
Short circuit pre-wash temperature
sensor.
Short circuit in the wiring; damp in the
connector.
216
Pre-wash temperature
sensor break
Cable to pre-wash temperature sensor
broken.
Connector incorrectly connected;
crimp connection inadequate
217
Wash tank low temp
Wash tank low temperature
heating element defective; Water
transfer;
Insufficient heating capacity;
Temperature sensor wrongly installed
218
Circ pump error
Signal "circulation pump error" pending
Motor overload switch triggered
219
Low temperature PKSP
Heating element defective; Insufficient
heating capacity; Temperature sensor
wrongly installed;
Water transfer;
Refilling;
Suction too strong
220
Excessive temperature
PKSP
Actual temperature in tank too high;
Contactor sticking;
Relay on I/O circuit board sticking;
Temperature sensor defective; Plug
contact temperature sensor with high
resistance
221
Malfunction p
ump KV
Signal "circulation pump error of KV"
pending
Motor overload switch triggered
222
Malfunction p
ump VA
Signal "circulation pump error of VA"
pending
Motor overload switch triggered
223
Malfunction p
ump WT7
Signal "circulation pump error of WT7"
pending
Motor overload switch triggered
224
Malfunction p
ump WT6
Signal "circulation pump error of WT6"
pending
Motor overload switch triggered
225
Malfunction p
ump WT5
Signal "circulation pump error of WT5"
pending
Motor overload switch triggered
226
Malfunction p
ump WT4
Signal "circulation pump error of WT4"
pending
Motor overload switch triggered
227
Malfunction p
ump WT3
Signal "circulation pump error of WT3"
pending
Motor overload switch triggered
228
Malfunction p
ump WT2
Signal "circulation pump error of WT2"
pending
Motor overload switch triggered
229
Malfunction p
ump WT1
Signal "circulation pump error of WT1"
pending
Motor overload switch triggered
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
valid from: 2005-09-01
Update: 2006-11-14 / S.5
W e reserve the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Содержание K-Tronic
Страница 1: ......