Service Instructions Dishwashing Machine Model K-Tronic
Ident No.: 9627429
Page 26/30
515
Thermal contact
compressor
Thermal contact on compressor has
triggered
Find cause for raised
temperature
Malfunction must also be
acknowledged in addition
Drying
610
Low temperature
drying zone
Tolerance range exceeded
611
Drying temp. sensor
short
cut
Short circuit drying temperature sensor.
Short circuit in the wiring; damp in the
connector.
612
Drying temp. sensor
break
Cable to drying temperature sensor
broken.
Connector incorrectly connected;
crimp connection inadequate
613
Drying fan error
Motor overload switch fan triggered
614
Excessive temperature
Drying
Permissible maximum exceeded
615
Suction fan
malfunction
Suction fan power switch triggered
Conveyor system
710
End switch activated
Crockery at the conveyor end
Remove crockery
711
Error impulse
transmitter transport
If the impulse switch mode is
PARAMETERISE d and the transport
activated, a cycle impulse must be
received for each time unit; in the event
of an error, the units are switched to
continuous running
Reed switch defective; Magnet on rotary
disk incorrectly positioned
713
Malfunction
rinse agent
Rinse agent empty?
714
Malfunction detergent
Detergent empty?
715
Malfunction gas
module
See gas module description
716
External water
treatm. malfunction
See description of the water treatment
equipment
717
External conveyor
see circuit diagram description
CAN communication
815
KMM connection
interrupted
CAN connection interrupted;
KMM (communication module) does not
respond
Datei: 2K_9628652_Serviceanleitung-MIKE_EN_2005-09-01.doc
valid from: 2005-09-01
Update: 2006-11-14 / S.5
W e reserve the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174