15.4 Parameter list
Par.
No.
Configuration
options
Use as
value
range
Unit
Factory
setting
Note
101
Wash program
Key 1
Parameters
1 .. 50
-
1
Allocate the wash program to the
key 1
Assignment adjustable
102
Wash program
Key 2
Parameters
1 .. 50
-
3
Allocate the wash program to the
key 2
Assignment adjustable
103
Wash program
Key 3
Parameters
1 .. 50
-
4
Allocate the wash program to the
key 3
Assignment adjustable
104
Rinse agent
Dosing quantity
Parameters
0.10 .. 1.00 ml/Liter
water
0.2
Value can be read from the rinse
aid container label (dependant on
water quality)
105
Rinse program
Dosing quantity
Parameters
0.1...
20.0
ml/Liter
water
2.0
Value can be read from the deter-
gent container label (dependant on
water quality)
106 Hardness degree Parameters
0 .. 50
[°dH]
0
The quantity of soft water available
between two regenerations de-
pends on
the hardness of the water.
107
Beep ON/OFF
Parameters
0/1
-
1
Switch on/off acoustic ready mes-
sage
108
Mode
“Clear” display
Parameters
0/1
-
“Clear” display
0: via INFO 420, 520
1: display of special characters
111
Total Operation
time
Indication
Indication
5 figures
h
Operation time
query only
112
Total number of
wash cycles
Indication
5 figures
-
Wash cycles/loads,
query only
113
Total number of
wash cycles since
last reset
Indication
5 figures
-
Wash cycles/loads,
re-setting possible
114
Serial number
Indication
8 figures
-
Option for calling up works param-
eters
119 IR-communication Parameters
0/1
-
1
It is possible to shut off communi-
cation via IR interfaces. (0)
120
Total number of
wash cycles Indi-
cation
Parameters
0/1
-
0
Effective only upon power supply
reset ON/OFF
ATTENTION!
All changes to ser-
vice parameters will be
reversed.
Power supply reset must be car-
ried out within 5 minutes, other-
wise factory settings will not be
loaded.
Without power supply reset, the in-
formation 123 will be displayed.