ERR.-No. Description
Possible cause
203
No change detected by the level
switch during emptying
Boost pump defective
Booster pump plug connector loosened
Start capacitor defective
Plug connector loosened
Boiler level switch defective
No boost pump signal to - from in-
put/output circuit boards
Check boost pump DSP / S2 using man-
ual control
204
Following the end of post-rinse
time, still no change detected
at the level switch
See 203
205
Temperature increase not
reached
Boiler heating defective / thermal fuse
radiator
Temperature sensor defective, incorrect
installation position
Boiler contactor defective, performance
switch loosened
No signal from ON/OFF circuit boards
206
Wash time increase
Boiler not ready for rinsing early enough
(boiler level/ boiler temperature)
Boiler heating defective / thermal fuse
radiator
Temperature sensor defective
Boiler contactor defective, performance
switch loosened
No signal from ON/OFF circuit boards
210
Temperature sensor short circuit Check sensor cable (plug contacts)
Replace sensor
Install sensor correctly
211
Temperature sensor interruption See 210
212
Actual boiler temperature too high Contactor sticking
Incorrect sensor / defective sensor
Check sensor / cable (contact plug
MIKE II XA5)
301
Number of circulatory pumping
cycles exceeded.
Tank level analysis disrupt-
edTank level analysis disrupted
Booster pump yield too low
Rinse jets soiled
Air trap soiled
Booster pump rotor defective
Condensate in level pipe
Hose kinked / loose / not watertight
302
When pumping out during rinse
program, level does not fall below
level 1.
Fresh water supply insufficient
(water faucet closed)
Drain pump soiled / defective
Rotor loose
Drain pump plug connector loose
Start capacitor defective
Tank level analysis disruptedTank level
analysis disrupted
Aquastop not closing completely
No signal from ON/OFF circuit boards
303
Level does not fall below level 3
after time (drain pump ON)
See 302