31 / 44
9625762
Par.
No.
Configuration
options
Use as
value
range
Unit
Factory
setting
Note
121
Activate mainte-
nance display
Parameter 0 .. 3
0
0 = OFF
1 = Operating hours
2 = Batch counter
3 = Operating hours or number of
batches
122
Operating hours
reference value
Parameter 10 .. 10000 Hour
0
Evaluation according to operating
hours
123 Batch counter ref-
erence value
Parameter 100 .. 50000 Loads
0
Evaluation according to number of
batches
124
Reset mainte-
nance display
Parameter 0/1
0
0 = NO
1 = YES
Note: When using the M-Com-
mander an upload and download is
necessary for the reset procedure.
201
Machine type
Parameters
1 – 9
-
2
1: FV 40.2 / FV 60.2 / FV28 GiO-M
2: FV 130.2 / FV 250.2 / DV 270.2
3: DV 80.2 / DV 200.2
4: DV 120.2 / DV 125.2 /
DV 200.2PW
5: FV 70.2D / FV 40.2TL /
TopClean60
6: FV 130.2 TL / FV 250.2 TL /
DV 270.2 TL
7: DV 80.2 TL / DV 200.2 TL
8: DV 120.2 TL / DV 125.2 TL /
DV 200.2 TL PW
Attention!
Only assignment list
and machine sequences change –
no parameters
202 Must be-tank tem-
perature
Parameters
10 ... 80
(50 .. 176)
°C/°F
60
Standard for all the rinse programs
on one appliance! Output depend-
ent on definition.
203
Pre-rinse time
Parameters
0 ... 8
sec.
0
See pre-rinse process step
204
Post-rinse time
Parameters
4 ... 30
sec.
8
Energizing duration for the booster
pump
(running time limited by P306!!)
205 Operation indica-
tor
Parameters
0 .. 8
-
1
Definition of the information which
is to be switched via the poten-
tial-free contact
0 – No information
1 - Filling/Heating, ready for wash-
ing/washing or pumping out
2 – Filling/Heating, ready for wash-
ing/washing
3 - Filling / Heating
4 - Ready for washing
5 - Washing
6 - Draining
7 - Error
8 – Not status
machine OFF
and Draining
9 - Reserve
10 - Not status Machine OFF