ERR.-No. Description
Possible cause
304
Temperature increase not
reached
Tank heating defective / thermal fuse
Radiator
Temperature sensor defective, incorrect
installation position
Tank protection defective, performance
switch loose
305
Boiler content quantity insufficient
for rinsing. Level 2 not reached
See 301
Ventilation valve soiled
Level switch defective
Plug connector loosened
306
Tank level analysis disrupted
Tank level analysis disruptedTank
level analysis disrupted
Check tank level
Level sensor air catch / check hose
307
Tank level sensor defective
Connection plug loosened
Sensor defective
Replace input/output circuit boards
308
Hood drive malfunction
motor defective, limit switch jammed
309
Hood drive malfunction,
maximum current exceeded
Hood jammed, Spindle jammed, Motor
jammed, descale
310
See 210
See 210
311
See 211
See 211
312
See 212
See 212
Table 3: Error messages
Should information or fault numbers not shown in the tables be indicated, or should the
suggested measure not lead to the elimination of the fault, please notify a customer ser-
vice technician.